INSTALLATION & OPERATION MANUAL 10301 REV 0 (06/21)

 PAGE

16    

OF 20

Gas Fired Steamer

T

roubleshooting

Adjustments

Troubleshooting

 

 

WARNING

At least twice a year, have an authorized service person clean and adjust the unit for maximum performance.

 

 

WARNING

Adjustments  and  service  work  may  be  performed  only  by  a  qualified  technician  who  is  experienced  in,  and 

knowledgeable with, the operation of commercial gas cooking equipment. However, to assure your confidence, 

contact your authorized service agency for reliable service, dependable advice or other assistance, and for 

genuine factory parts.

All units are adjusted at the factory.  In case of operation problems at initial installation, check type of gas and manifold 

pressure and compare it with information on rating plate.

Troubleshooting

 

P

ilot

 L

ight

 D

oes

 N

ot Come On

1.  Gas supply to unit is “OFF.”

2.  Manual shut off valve is “OFF.”

3.  Power switch is not turned “ON.”
4.  Probe not sensing the water level, will not call for ignition.
5.  Ignitor or ignition module not functioning.

B

urners

 P

roduce

 C

arbon

 D

eposits

1.  Wrong orifice size.
2.  Wrong gas supply.

3.  Incorrect pressure at supply.
4.  Dirty primary air openings.
5.  Not enough primary air.

Water

 Flows

 into Cooking

 C

ompartment

1.  Probes not sensing water, thereby not operating fill solenoid.

2.  Scale build-up on operating probe inside generator.

3.  Water fill solenoid valve is not closed. Check for scale or foreign particles lodged in diaphragm or core tube of valve.

These problems are an indication of severe harmful water conditions which should be corrected immediately to avoid 

damage to the components and performance of the steamer.

Содержание CROWN SX-10G3

Страница 1: ..._________ WARNING Improper installation adjustment alteration service or maintenance can cause property damage injury or death Read the installation operating and maintenance instructions thoroughly b...

Страница 2: ...intenance instructions thoroughly before installing operating or servicing this equipment NOTICE PURCHASER Instructions to be followed in the event that the operator of this appliance smells gas must...

Страница 3: ...0 Gas Fired Steamer RETAIN THIS MANUAL FOR FUTURE REFERENCE Table of Contents Important Notes For Installation and Operation 2 Service Connections 4 Installation Instructions 7 Performance Check 10 Op...

Страница 4: ...ensive Water Treatment System which exceeds our minimum water requirements Proof of installation and proper cartridges replacement is required for warranty coverage Water supply to Crown Steam Group s...

Страница 5: ...r cartridges replacement is required for warranty coverage Water supply to Crown Steam Group steamers must be within these guidelines Total dissolved solids Less than 60 PPM Chlorine Less than 1 5 PPM...

Страница 6: ...e with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 or the Canadian Electrical Code CSA C22 2 as applicable Ventilation must be provided in accordance wi...

Страница 7: ...late on the unit indicates the type of gas your unit is equipped to burn DO NOT connect to any other gas type 2 A 3 4 NPT line is provided at rear for the connection Each compartment is equipped with...

Страница 8: ...ing guidelines Failure to comply with Water Quality Statement on page 4 may void the warranty Water supplies vary from one location to another Other factors affecting steam generation are iron content...

Страница 9: ...rainage This negative pressure prevents steam leakage around the door gasket and helps draw the steam through the cooking compartment Steam leakage at the door may indicate a plugged or improperly ins...

Страница 10: ...set timer to the 5 minute position With door open observe that no steam is entering the compartment and that the COOKING light is OFF 5 Close compartment door The COOKING light should now be illuminat...

Страница 11: ...le will be interrupted if the door is open during the cooking cycle resume cooking by closing the door MAIN POWER SWITCH On The generator will automatically fill and begin heating to the pre set tempe...

Страница 12: ...itional cooking time is necessary Cooking time for frozen foods depends on amount of defrosting required If time permits allow frozen foods to partially thaw overnight in a refrigerator This will redu...

Страница 13: ...le brush and mild detergent clean inside the drain opening ensuring there is no food residue or blockage Clean the drain screen and replace in its original position 6 Leave door slightly open when ste...

Страница 14: ...r the finish of the stainless steel NEVER RUB WITH A CIRCULAR MOTION Soil and burnt deposits which do not respond to the above procedure can usually be removed by rubbing the surface with SCOTCH BRITE...

Страница 15: ...pillage Remove hose Screw deliming plug back so it seals tightly Turn power switch to on If there is no deliming plug on the side of the steamer check with your local service agency for proper delimin...

Страница 16: ...pressure and compare it with information on rating plate Troubleshooting Pilot Light Does Not Come On 1 Gas supply to unit is OFF 2 Manual shut off valve is OFF 3 Power switch is not turned ON 4 Probe...

Страница 17: ...s into Drain During Shut Down 1 Condensate solenoid valve and or fill solenoid valve is not closed Check for scale or foreign particles lodged in diaphragm or core tube of valve Water Not Being Suppli...

Страница 18: ...INSTALLATION OPERATION MANUAL 10301 REV 0 06 21 PAGE 18 OF 20 Gas Fired Steamer Notes...

Страница 19: ...INSTALLATION OPERATION MANUAL 10301 REV 0 06 21 PAGE 19 OF 20 Gas Fired Steamer Notes...

Страница 20: ...placement parts and occasional professional service may be necessary to extend the useful life of this appliance When service is needed contact a Crown Authorized Service Agency or your dealer To avoi...

Отзывы: