PARTS

INTAKE ASSEMBLY

QTY

PART

A

MIXED  FLOW ASSEMBLY 

(FAN  UNIT)

QTY

PART

B

FAN  UNIT MOUNTING  PLATE

QTY

PART

C

1

1

1

FLEXIBLE  DUCT (25  FEET)

FLEXIBLE  DUCT CLAMPS

QTY

QTY

PART

D

PART

E

1

3

10-32 x 1/2  PHILLIPS  HEAD SCREW 

&

 

QTY 

PART

F

CABLE TIE  MOUNT

QTY

12

10-32  LOCKNUT

TEMPERATURE  PROBE

CONNECTOR

TEMPERATURE  PROBE 

WIRE (30  FEET)

QTY 

PART

5

(One Extra)

\

(One Extra)

H

QTY 

PART 

K

QTY 

PART 

M

#10 x 5/8 WOOD SCREW 

QTY

12

WIRE TIE

INTAKE TEMPLATE

QTY

24

QTY

1

Page  3

PART

G

PART

J

PART

L

PART

N

Содержание Cool Series

Страница 1: ...d these instructions thoroughly before installing assembling this product PRODUCT FEATURES Removes air from enclosed areas with minimal noise Inline mixed flow duct fan is quieter and more efficient than centrifugal fans Operates only when needed minimizing noise and dust M iddle Atlantic Products I 00248 Rev C ...

Страница 2: ...Pour usage de ventilation generale seulement ne pas utiliser pour echappement nocifs ou explosives matieres et les vapeurs A Ac CAUTION Automatically operated device to reduce the risk of injury disconnect from power supply before performing any maintenance operations ATTENTION Dispositif fonctionnement automatique pour reduire le risque de blessures debrancher a partir de source de courant avant ...

Страница 3: ...BLE DUCT CLAMPS QTY QTY PART D PART E 1 3 10 32 x 1 2 PHILLIPS HEAD SCREW QTY PART 5 F CABLE TIE MOUNT QTY 12 10 32 LOCKNUT TEMPERATURE PROBE CONNECTOR TEMPERATURE PROBE WIRE 30 FEET QTY PART 5 One Extra One Extra H QTY PART 1 K QTY PART 1 M 10 x 5 8 WOOD SCREW QTY 12 WIRE TIE INTAKE TEMPLATE QTY 24 QTY 1 Page 3 PART G PART J PART L PART N ...

Страница 4: ...te to mark installation location NOTE Hole size is 7 1 8 3 Cut hole using desired method hand saw power saw etc FIGURE A INTAKE ASSEMBLY INSTALLATION 4 Insert Intake Assembly A into the hole FIGURE B 5 Tighten the four screws on the Intake using a Phillips Head screwdriver The clips will automatically swing into the proper position securing the Intake Assembly FIGURE C ...

Страница 5: ...n mount on Mounting Plate in two directions adjustable slots allow for two inch shift either way off center position FIGURE B 2 Determine mounting location in attic Mounts to joists or structurally sound flat surface NOTE Make sure airflow faces away from Louvered Intake airflow shown on label affixed to fan unit and on electrical box 3 Mount Fan Unit as desired using customer supplied hardware FI...

Страница 6: ... to properly gauge temperature See FIGURE A for an example of a Temperature Probe Assembly installation 2 Drill a 1 8 hole where the Temperature Probe M will be located 3 Run Temperature Probe Wire along joist and secure with provided Wire Ties L Wood Screws J and Cable Tie Mounts G Place Probe lead through previously drilled 1 8 hole 4 If desired cut the stripped ends of the Temperature Probe Wir...

Страница 7: ...UCT INSTALLATION 2 Pull back outer insulation on both ends 3 Attach Flexible Duct to Louvered Intake with provided Clamp E FIGURE A 4 Cut Flexible Duct to appropriate length 5 Attach Flexible Duct to Fan Unit with provided Clamp E FIGURE B NOTE Duct Tape can be used with the Clamps for extra hold 6 Plug in the power cord and your DUCT COOL is ready for use FIGURE C FIGURE B Page 7 ...

Страница 8: ...F ALL OTHER WARRANTIES OF ANY KIND EITHER EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW IN NO EVENT SHALL THE COMPANY BE LIABLE FOR ANY SPECIAL INCIDENTAL INDIRECT OR CONSEQUENTIAL DAMAGES WHATSOEVER INCLUDING WITHOUT LIMITATION DAMAGES FOR LOSS OF BUSINESS PROFITS BUSIN...

Отзывы: