Mains Voltage Selection
These units are capable of operating over a wide range of AC mains supply voltages by
means of a comprehensive set of user-selectable settings. It is important to ensure that
the correct voltage setting has been selected for the level of local mains voltage supply for
safe, uninterrupted operation of the units. The unit is shipped with dedicated mains voltage
selected and the correct fuse installed.
There are two MAINS VOLTAGE SELECTION switches at the back of the unit. Voltage
selection is achieved by moving the switches into the correct positions using a screwdriver
blade, as shown by the inscription at the side of the access holes.
In this way the unit is set up for operation at one of the following mains supply ranges:
DO NOT CHANGE THE VOLTAGE SETTING WITHOUT FIRST
UNPLUGGING THE MAINS LEAD. TO AVOID RISK OF FIRE ONLY
REPLACE WITH THE CORRECT VALUE FUSE AS INDICATED ON THE UNIT
FOR THE SPECIFIC VOLTAGE SETTING.
Replacing the Mains Fuse
.
In the event of incorrect position of the mains voltage selectors, a mains power surge or
underrated fuse value, the mains fuse on the front panel may blow and the power supply unit
will be out off function. Unplug the mains cable, check the fuse and replace if necessary.
Also check, that the voltage selection is correct for the mains supply level before
switching the unit ON again.
In the event of repeated failure of the mains fuse please consult your VENICE dealer
from where you purchased the unit.
THIS UNIT CONTAINS NO USER SERVICEABLE PARTS. REFER ALL
SERVICING TO QUALIFIED SERVICE PERSONNEL OR YOUR VENICE DEALER.
NOMINAL VOLTAGE
OPERATING VOLTAGE RANGE
VAC
VAC
240
204 - 264
220/230
188 - 253
120
102 - 132
100
85 - 110