16 Manual Number 9018558 • Revision H, April 13, 2021
SECTION 5 CONFORMANCE
5.1
INSTRUCTIONS FOR CONTINUED AIRWORTHINESS
No periodic scheduled maintenance or calibration is necessary for continued airworthiness of the
TC120 DC/DC Converter. If the unit fails to perform to specifications, the unit must be removed
and serviced by Mid-Continent Instruments and Avionics or their authorized designee.
5.2
ENVIRONMENTAL QUALIFICATION STATEMENT
MODEL NUMBER:
TC120
PART NUMBER:
6430120-( )
DESCRIPTION:
DC/DC Converter
CERTIFICATION:
FAA TSO-C71
MANUFACTURER:
True Blue Power, a division of Mid-Continent Instrument Co., Inc.
ADDRESS:
9400 E. 34
th
St. North, Wichita, KS 67226, USA.
SPECIFICATION:
Test Specification (TS) 627 Test Data Sheet (TDS) 627
STANDARD
:
RTCA DO-160, Rev G, dated 12/08/10
CONDITIONS
SECTION
DESCRIPTION OF TEST
Temperature and Altitude
4
Category F2
Temperature Variation
5
Category S2
Humidity
6
Category B
Operational Shock and Crash Safety
7
Category B
Vibration
8
Fixed Wing: Category R; Curve C, C1
Rotorcraft: Category U, Curve G
Explosion
9
Category X
Waterproofness
10
Category X
Fluids
11
Category X
Sand and Dust
12
Category X
Fungus
13
Category F
Salt Fog
14
Category X
Magnetic Effect
15
Category Z
Power Input
16
Category B(XX)
Voltage Spike
17
Category B
Audio Frequency Conducted Susceptibility
18
Category R
Induced Signal Susceptibility
19
Category X
Radio Frequency Susceptibility
20
Category X
Emission of Radio Frequency Energy
21
Category M
Lightning Induced Transient Susceptibility
22
Category X
Lightning Direct Effects
23
Category X
Icing
24
Category X
ESD
25
Category A
Fire, Flammability
26
Category X
REMARKS: