Mid-Continent Instrument SAM MD302-3 Скачать руководство пользователя страница 2

 

Manual Number 9018233, Revision A 

Mid-Continent Instruments and Avionics 

 

December 22, 2014

 

 

FOREWORD 

 
 
 
This manual provides information intended for use by persons who, in accordance with current 
regulatory requirements, are qualified to install this equipment. If further information is required, 
please contact: 
 

Mid-Continent Instruments and Avionics 

Attn: Customer Service Dept. 

9400 E. 34

th

 St. N. 

Wichita, KS 67226 USA 

Phone 316-630-0101 

Fax 316-630-0723 

[email protected] 

www.mcico.com 

 
 
 

We welcome your comments concerning this manual. Although every effort has been made to 

keep it free of errors, some may occur. When reporting a specific problem, please describe it 

briefly and include the manual part number, the paragraph/figure/table number, and the page 

number.  Send your comments to: 

 
 
 

 

Mid-Continent Instruments and Avionics 

Attn: Customer Service Dept. 

9400 E. 34

th

 St. N. 

Wichita, KS 67226 USA 

Phone 316-630-0101 

Fax 316-630-0723 

[email protected] 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

© Copyright 2014 

Mid-Continent Instrument Co., Inc. 

Содержание SAM MD302-3

Страница 1: ...del MD302 3 Mid Continent Instruments and Avionics Mid Continent Instrument Co Inc dba Mid Continent Instruments and Avionics 9400 E 34th Street N Wichita KS USA 67226 PH 800 821 1212 Manual Number 90...

Страница 2: ...7226 USA Phone 316 630 0101 Fax 316 630 0723 ks customerservice mcico com www mcico com We welcome your comments concerning this manual Although every effort has been made to keep it free of errors so...

Страница 3: ...3 Manual Number 9018233 Revision A Mid Continent Instruments and Avionics December 22 2014 REVISION HISTORY ECO Rev Date Approved Detail A 12 22 2014 BMC Production release...

Страница 4: ...INSTALLATION 8 2 1 GENERAL INFORMATION 8 2 2 PARTS LIST 8 2 3 EQUIPMENT LOCATION 9 2 4 LIMITATIONS 10 2 5 MODIFICATIONS 11 2 6 CABLE HARNESS 12 2 6 1 WIRE GAUGE SELECTION 12 2 6 2 CONFIGURATION MODULE...

Страница 5: ...for maximum flexibility for installation in retrofit or modern instrument panels and equipment bays Its size and AnyWayTM selectable orientation allows it to be installed almost anywhere and in less s...

Страница 6: ...Sub with Configuration Module MCIA p n 9017275 Pneumatic fittings MCIA p n 9017642 Mounting Mount from front uses 4 6 32 cap screws TABLE 1 2 1 2 3 PERFORMANCE LIMITS Characteristics Attitude Pitch A...

Страница 7: ...Output Speed Label Description High Low 203 altitude rel 29 92 x x 204 baro altitude x x 205 mach number x x 206 computed airspeed x x 212 altitude rate x x 215 impact pressure x x 217 static pressure...

Страница 8: ...g and before installation of the equipment ensure that power is applied only to the pins specified in the interconnect diagram 2 2 PARTS LIST When unpacking this equipment make a visual inspection for...

Страница 9: ...tic connections and routing must be allowed Be aware of routing cables near other electronics or with other wire bundles that may be susceptible to high energy flow Avoid sharp bends in cabling or hos...

Страница 10: ...plete TSO The MD302 meets all TSO requirements for applicable functions slip but does not meet requirements associated with functionality that is not present in the unit rate of turn A note below desc...

Страница 11: ...rrent modification releases of the MD302 Standby Attitude Module MOD 0 Modification MOD 0 is identified on the nameplate by the lack of marking on the MOD numbers 1 through 9 i e 1 9 are visible Mod 0...

Страница 12: ...TION Wire gauge should be 22 AWG Use of PTFE ETFE TFE Teflon or Tefzel insulated wire is recommended for aircraft use per MIL DTL 16878 or equivalent Additionally for data signals associated with ARIN...

Страница 13: ...of the D Sub connector as follows Board TP1 config return D Sub pin 15 Board TP2 config data D Sub pin 14 Board TP3 config clock D Sub pin 10 Board TP4 config power D Sub pin 5 5 Install the D Sub Bac...

Страница 14: ...18 Backshell Size 9 2 1 9017274 Cover Backshell 3 1 9017184 1 PCB Assy Config Module 4 1 9016479 Kit DSub 15pin HD 5 1 part of 9016479 DSub Backshell Spring Clip 6 1 part of 9016479 DSub Slide Lock Si...

Страница 15: ...he correct port on the back of the unit during installation WARNING Lock quick disconnect before connecting to the unit to avoid damaging the O ring 2 8 INSTALLATION COMPLETION Prior to operating the...

Страница 16: ...22 2014 FIGURE 2 5 MD302 OUTLINE DRAWING TABLE 2 2 MD302 UNIT VERSIONS Unit Versions Part Number Bezel Battery 6420302 1 Black Yes 6420302 2 Black No 6420302 3 None No 6420302 4 Gray Yes 6420302 5 Gra...

Страница 17: ...settings file AIRSPEED_MINIMUM_20_KNOTS AIRSPEED_MINIMUM_30_KNOTS AIRSPEED_MINIMUM_40_KNOTS ARINC_SPEED_LOW ARINC_SPEED_HIGH DISPLAY_ORIENTATION_HORIZONTAL DISPLAY_ORIENTATION_VERTICAL_RIGHT DISPLAY_...

Страница 18: ...e settings were accepted 6 Remove the USB stick while power remains on 7 The MD302 will reboot and illuminate STATUS green to indicate normal operation with the new settings 8 Reinstall USB cover If t...

Страница 19: ...02 with the test pressure stabilized at 5 000 feet Both calibrations may be done at the same time with a combined P S tester The procedure is 1 Power off MD302 2 Uncover the USB port and insert flash...

Страница 20: ...nd can be found on the product website www flySAM com Below are instructions for updating the unit software PREPARATION 1 Prepare software update file A Obtain a USB flash drive from Mid Continent Ins...

Страница 21: ...ze the horizon reference o Another cause might be pitot static sources swapped or significant positive pressure on the static source o If the error does not clear it could be an internal system failur...

Страница 22: ...itude 55K 15 000 ft Temperature Variation 5 Category S2 Humidity 6 Category A Operational Shock and Crash Safety 7 Category B Vibration 8 Fixed Wing Category R Curves B B1 Helicopter Category U Curve...