Manual Number 9018233, Revision A
Mid-Continent Instruments and Avionics
December 22, 2014
2.4 LIMITATIONS
The conditions and tests for TSO approval of this article are minimum performance standards. Those
installing this article on or in a specific type or class of aircraft must determine that the aircraft installation
conditions are within the TSO standards, specification of the article, and deviations listed below. TSO
articles must have separate approval for installation in an aircraft. The article may be installed only
according to 14 CFR part 43 or the applicable airworthiness requirements.
There are some portions of the approved TSOs which represent outdated requirements or do not apply to
the product. These items are highlighted below and have been submitted to and approved by the FAA as
deviations to the TSO certifications of the product. In the case of FAA TSO and EASA ETSO-C3e, the
MD302 has been approved as an ‘incomplete TSO’. The MD302 meets all TSO requirements for
applicable functions (slip) but does not meet requirements associated with functionality that is not present
in the unit (rate of turn). A note below describes further details regarding the temperature requirements of
FAA TSO-C113a, but does not represent a deviation.
FAA TSO-C2d: Airspeed Instruments
instrument is not labeled with “Airspeed” or “IAS”
FAA TSO-C3e: Turn and Slip Instrument
instrument does not provide rate-of-turn functionality
FAA TSO-C4c: Bank and Pitch Instruments
dielectric
strength/insulation
resistance
does not apply due to electronic components between
chassis and connector pins
FAA TSO-C10b: Altimeter, Pressure Actuated, Sensitive Type
instrument is not labeled with “Altitude” or “ALT”
graduation increments are every 25 feet instead of 20 feet
FAA TSO-C113a: Airborne Multipurpose Electronic Displays
display is operable but marginally usable at -30°C. Display is fully functional at temperatures
higher than -30°C.
Heading Display Function
Does not provide independent heading data, the ARINC data is displayed without
reprocessing; if ARINC data is lost the display will read “---“.