Micsig DP10007 Скачать руководство пользователя страница 2

Rise Time

Maximum Differential 

Test Voltage

(DC+AC  PK)

Maximum input 

common mode voltage

Input referred noise

Common Mode 

Rejection Ratio

Input Impedance

Output Voltage

Overrange Alarm

Input cable length

Output cable length

Model

Bandwidth

Attenuation

Gain accurecy

Power Supply

Power

Dimension

Please read this manual carefully before use!

Introduction

Micsig DP series differential probe can convert the input high voltage 

differential signal into single-ended Low-voltage signal, and display 

through the oscilloscope. Available with low and high attenuation

option, the differential measurement voltage can reach up to 700V/

1300V/5600V.

1

2 Specification

Operating  Humidity 

Operating 

Temperature

15mVrms(10X)

8M

Ω

/1.25pF(differential)

4M

Ω

/2.5pF(single-ended 

 DP10007

100MHz

3.5ns

10X

100X

±

1%

70V

(

10X

)

700V

(

100X

)

-80dB@50Hz

-50dB@1MHz

7V

Button light flashes

DC  5V,USB Supply

1.25W

14.5cm*6cm*2.7cm

Approx 45cm

Approx 90cm

0 ~40

10%~85%

CAT II    600V

CAT I   1000V

-60dB@20KHz

-40dB@10MHz

60mVrms(100X)

to ground)

40mVrms(50X)

10M

Ω

/1pF(differential)

5M

Ω

/2pF(single-ended 

 DP10013

100MHz

3.5ns

50X

500X

±

2%

130V

(

50X

)

1300V

(

500X

)

80db(DC)

60db(100KHz)

50db(1MHz)

CAT  II   1000V

230mVrms(500X)

160mVrms(200X)

50M

Ω

/1.25pF(differential)

25M

Ω

/2.5pF(single-ended 

 DP20003

100MHz

3.5ns

200X

2000X

±

2%

560V

(

200X

)

5600V

(

2000X

)

920mVrms(2000X)

to ground)

to ground)

CAT 

 Ⅲ

   1000V

80db(DC)

60db(100KHz)

50db(1MHz)

3V

3V

0.85W

0.85W

Содержание DP10007

Страница 1: ...To avoid an electric shock all devices that require grounding must be connected to earth ground Before making connections to the input or output terminals of the probe ensure that the test instrument is properly grounded if necessary Measurement safety Always be aware of the voltage rating of the probe and the measurement accessories you are using and of the maximum amplitude of the signal you int...

Страница 2: ...asurement voltage can reach up to 700V 1300V 5600V 1 2 Specification Operating Humidity Operating Temperature 15mVrms 10X 8MΩ 1 25pF differential 4MΩ 2 5pF single ended DP10007 100MHz 3 5ns 10X 100X 1 70V 10X 700V 100X 80dB 50Hz 50dB 1MHz 7V Button light flashes DC 5V USBSupply 1 25W 14 5cm 6cm 2 7cm Approx45cm Approx90cm 0 40 10 85 CAT II 600V CAT I 1000V 60dB 20KHz 40dB 10MHz 60mVrms 100X to gro...

Страница 3: ...illoscope Connect the probe output BNC to the oscilloscope channel input Note make sure the oscilloscope is properly grounded if necessary 3 Set the appropriate attenuation range according to the measured voltage 4 Connecting the input to the device under test Using the appropriate input accessory connect the probe to the device under test to start the measurement If the attenuation range indicato...

Страница 4: ...uafeng International Robot Industrial Park Hangcheng Rd Bao an District Shenzhen Guangdong China 518126 WEB www micsig com TEL 86 755 88600880 E mail sales micsig com 3 While measuring a high frequency signal don t touch the end of the input lead with your hand or other objects Otherwise it may affect the accuracy of the measurement 4 Ensure that you use an oscilloscope with an input impedance of ...

Отзывы: