I n s t a l l a t i o n a n d u s e r m a n u a l
|
5
HEA
T
PUM
P
M
IC
R
O
W
E
LL
H
P
C
O
M
P
A
C
T
3. PRODUCT DESCRIPTION AND TECHNICAL SPECIFICATION
3.1 Technical data
HP 900 COMPACT
HP 1200 COMPACT
Air temperature/water temperature
25°C/10°C
25°C/20°C
25°C/10°C
25°C/20°C
Heating output (kW)
9.03
8.57
12.01
11.07
Power consumption (kW)
1.55
1.57
2.06
2.03
Coefficient of Performance (C.O.P.)
5.80
5.44
5.81
5.45
Recommended swimming pool capacity (m
3
) (with
a cover/without a cover)
40/30
60/40
Energy class
A
A
Operating temperature – air (°C)
5-40
5-40
Optional swimming pool water temperature range (°C)
5-40 (60)
5-40 (60)
Air flow (m
3
/h)
2520
2520
Recommended water flow (m
3
/h)/pressure loss (kPa)
4-6/2-8
4-6/2-8
Feeding voltage/Protection (V/A)
230 / 20/1C
230 / 20/1C
Current-carrying capacity/max. current (A)
9.1
10.6
Coverage/Protection
IP X4/by zeroing
IP X4/by zeroing
Heat exchanger
Titan
Titan
Acoustic pressure level dB (A) 1m/2m/4m/8m
54/48/42/36
55/49/43/37
Water circuit connection (mm/cól, thread)
50/ 6/4“ internal
50/ 6/4“ internal
Max. recommended pipe length (m)
30
30
Net unit dimensions (w/h/d)
870/950/320
870/950/320
Gross unit dimensions (w/h/d)
1020/1080/450
1020/1080/450
Net/Gross weight (kg)
67/73
69/75
Refrigerant/filling weight (type/kg)
R410A/1.27
R410A/1.60
* The manufacturer reserves the right to change the parameters without any advance warning.
3.2 Swimming pool water parameters
The heat pump is designed for heating the swimming pool water, that must be in accordance with the
related sanitary requirements.
The limit values for the heat pump operation are the following: pH value ranging from 6.8 to 7.9; total
chlorine amount not exceeding 3 mg/l.
It is advised to keep the water hardness on the lower limit of the optimal range, i.e. closely above 8
°N.
3.3 Heat pumps dimensions
Water outlet
6/4“inner/l 50mm
Water inlet
6/4“inner/l 50mm
Controller
Power supply
230V/50Hz
470
70
69
5
87
5
96
5
94
0
42
5
36
0
32
0
870
546
WARNING: The manufacturer
reserves the right to make
modifications and innovations on the
product that do not have any
negative impact on its technical
feautures and parameters.