2. SAFETY MEASURES
WARNING: The product contains electric parts under pressure. Every operation
must be performed by a specialised technician. Risk of injury by electric current.
a)
The positioning of the heat pump must be in accordance with the STN 33 2000-7-702
standard, i.e. it must be placed at least 3,5 m from the swimming pool´s external border.
b)
The connecting circuit of the heat pump must be in accordance with the related standard
(STN 33 2000), must be equipped with a current protector with a 30mA interrupting current.
c)
Any kind of interference with the electric installation of the heat pump and with the feed
circuit must be performed only by a specialised technician.
d)
Do not install the heat pump at places that can get flooded by water.
e)
Make sure that children are kept away from the working area of the heat pump. The main
heat pump switch must be placed beyond the reach of children.
f)
Do not leave the heat pump in operation without a complete arrangement, including the
covers. Rotating fans may cause serious injuries. The internal pipe is warm during operation
and may cause burns when touched.
g)
If you notice any damage on the flexible cord of the heat pump or on the extension cord on
the inlet, turn off the circuit-breaker of the heat pump´s feed circuit immediately and
eliminate the failure.
h)
Any kind of repair of the heat pump or interference with the pressure cooling circuit, must be
performed only by a specialised technician.
i)
The product maintenance and operation must be performed in accordance with this user
manual, in the recommended terms and frequency.
j)
Make sure that you use only original spare parts.
In case of not following and keeping the above instructions, the warranty is not applicable.
The cooling circuit is filled with R410A refrigerant that consists of 2 components (R32/R125). These
components are considered as fluorocarbon greenhouse gases.
The product contains fluorocarbon greenhouse gases listed in the Kyoto Protocol:
R410A with the global warning potential (GWP) 1720
(R-32/125 50/50)
CH2F2 + CF3CHF2
1270 g (HP 900)
1600 g (HP 1200)