I n s t a l l a t i o n a n d u s e r m a n u a l
HP 900/1100/1500 BLACK Inverter
V e r s i o n : 0 1 / 2 0 2 2
P a g e
2 5
H
E
A
T
P
U
MP
M
I
C
RO
W
E
LL
H
P
“D” Defrosting parameters
Description
Code Unit.
Default Value
HP Black
Range
Start defrosting
temprature
D01
°C
-7
-7
-30~5.0°C
End Defrosting Temp
D02
°C
13
13
0.1~30.0°C
Defrosting Cycle
D03
min
45
45
30~90min
Max. Duration
D04
min
8
8
1~12 min
Defrost type
D06
/
0
0
0-normal/1-eco
Out Temp when Defrost
D07
°C
-30
-30
-30~10.0°C
Compensation offset
D08
°C
10
10
1~50.0°C
Defrost out Temp.
Deviation
D09
°C
14
14
1~50.0°C
Defrost ending Temp.
D10
°C
-18.4
-18.4
-30~5.0°C
“P” Water pump parameters
Description
Cod
e
Unit.
Default
Value
HP Black Range
Mode
P01 /
2
2
When P01=0, the circulation pump
will keep running when compressor.
When P01=1, the circulation
pump will stop in 2 min after
compressor off.
When P01=2, the circulation
pump will run at intervals P02 when
compressor off.
Interval
P02 min
30
30
0~120min
Duration
P03 min
3
3
0~30min
Advance
P04 min
1
1
0~30min
Whether to enable water
pump filtering
P05 /
0
0
0-no/1-yes
Pump filtration start time 1
P06 hour
10
10
0~23h
Pump filter off time 1
P07 hour
12
12
0~23h
Pump filtration start time 2
P08 hour
15
15
0~23h
Pump filter off time 2
P09 hour
17
17
0~23h
Note:
P01=0
Periodical mode (circulation pump on when heating/cooling)
P01=1
Periodical with 2min running after heating/cooling has stopped
P01=2
micro (periodical and sleep mode combination)
Please do not perform any changes without consultation with your seller first. Unauthorized
changes of the above parameters may result in undesired performance of the heat pump its
malfunction or damage. This applies also to system parameters Fxx, Hxx and Rxx.