background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Version: 01/2022

 

 

HEAT 

PUMP 

for swimming pool water 

heating & cooling 

        HP 900 BLACK Inverter   

HP 1100 BLACK Inverter 
HP 1500 BLACK Inverter 

 
 
 
 
 

 

Installation and user manual

 

 

Содержание HP 1100

Страница 1: ...Version 01 2022 HEAT PUMP for swimming pool water heating cooling HP 900 BLACK Inverter HP 1100 BLACK Inverter HP 1500 BLACK Inverter Installation and user manual ...

Страница 2: ...ns in your country regarding installation and usage of this heat pump which are valid in addition to this User manual Content 1 INTRODUCTION 3 1 1 Product description 3 1 2 Package checking 4 1 3 Waste disposal information 4 2 SAFETY MEASURES 5 2 1 Electrical safety 5 2 2 Usage precautions 5 2 3 Handling precautions 8 2 4 Transportation 8 3 TECHNICAL SPECIFICATION 9 3 1 Technical data 9 3 2 Swimmi...

Страница 3: ...ted operational air temperature range which is stated in section Technical data The heat pump enables heat gain from the external air surrounding the swimming pool through the compression expansion cycles of the heat carrying liquid The air is driven by a fan through the evaporator where it will deliver its heat to the heat carrying liquid the air is being cooled at the same time The heat carrying...

Страница 4: ...k the content It should include the following 1 The heat pump condensing unit the heat exchanger 2 This Installation and user manual 3 Four rubber silent blocks 1 3 Waste disposal information When using this heat pump in the European countries the following information must be followed DISPOSAL Do not dispose this product as unsorted municipal waste It is prohibited to dispose this heat pump in do...

Страница 5: ...nce such as welding machines motors or rotors WIFI WLAN routers or repeaters It is forbidden to alter electrical installation of the device It is also forbidden to alter any other part or functionality of the device 2 2 Usage precautions Do not cover or block the intake or exhaust opening ventilator and evaporator covers It is forbidden to block or cover the intake or exhaust openings with clothes...

Страница 6: ...not bear any responsibility concerning damages caused by inappropriate heat pump selection installation or application Do not pressurize the water heat exchanger higher than 0 25MPa 2 5bar By pressure of 0 5MPa 5bar the water heat exchanger gets irreversibly damaged It is advised to install a security valve with pressure threshold at 0 25MPa 2 5Bar before the heat exchanger Do not apply or use wat...

Страница 7: ...ow near inlet or outlet area otherwise the efficiency of the heater will be reduced or even stopped g Don t use or stock combustible gas or liquid such as thinners paint and fuel to avoid fire h In order to optimize the heating effect please install heat preservation insulation on pipes between swimming pool and the heater and please use a recommended cover on the swimming pool i Connecting pipes ...

Страница 8: ...ely onto the ground or any solid surface resulting in hard impact Please notify your reseller or distributor if you suspect that the unit was delivered damaged Unit may seem to work well at start but small damage can make the unit go out of order in short time In such case the unit must be inspected and approved for further use by your reseller Please notify your reseller or distributor if directl...

Страница 9: ...g ambient temperature range 7 C 43 C Water temperature range heating mode 15 C 35 C Water temperature range cooling mode 8 C 35 C Refrigerant R32 Sound level at 10m 1m dB A 40 49 41 50 43 53 Water pipe connection mm 50mm 50mm 50mm Compressor type GREE Rotary Water flow m h 2 7 3 3 4 4 Net dimension WxHxD mm 932x609x377 932x609x377 1015x766x427 Water pipe connection mm 50 Net weight kg 43 44 61 The...

Страница 10: ...he heat pump operation are the following pH value ranging from 6 8 to 7 9 total chlorine amount not exceeding 3 mg l salt content 6 wt wt Should you have different values of pH chlorine or salt please try to apply appropriate agents or contact your swimming pool builder to resolve the situation Above mentioned values are recommended for pools in general It is also advised to keep the water hardnes...

Страница 11: ...nd adapted if necessary according to actual installation condition a Swimming pool Heat pumps location The unit will perform well in any outdoor location provided that the following three factors are presented 1 Fresh Air 2 Electricity 3 Pool filter piping The unit may be installed virtually anywhere outdoors For indoor pools please consult the supplier Unlike a gas heater it has no draft or pilot...

Страница 12: ... ground surrounding the pipe which translates to about 3 to 5 increase in run time c Swimming pool Heat pumps Plumbing The Swimming Pool Heat Pumps exclusive rated flow titanium heat exchanger requires no special plumbing arrangements except bypass please set the flow rate according to the nameplate The water pressure drop is less than 10kPa at max Flow rate Since there is no residual heat or flam...

Страница 13: ...tting on the side of the basepan This fitting is designed to accept 20mm clear vinyl tubing which can be pushed on by hand and run to a suitable drain It is easy to mistake the condensation for a water leak inside the unit NB A quick way to verify that the water is condensation is to shut off the unit and keep the pool pump running If the water stops running out of the basepan it is condensation A...

Страница 14: ...be running to circulate water through the heat exchanger Start up Procedure After installation is completed you should follow these steps 1 Turn on your filter pump Check for water leaks and verify flow to and from the pool 2 Turn on the electrical power supply to the unit then press the key ON OFF of wire controller It should start in several seconds 3 After running a few minutes make sure the ai...

Страница 15: ... operating current 30mA The layout of power cable and signal cable should be orderly and not affecting each other Electric wiring Diagram For power supply 230V 50Hz Reference for protecting devices and cable specification Above data is subject to modification without notice Note The above data is adapted to power cord 10m If power cord is 10m wire diameter must be increased The signal cable can be...

Страница 16: ...rease variable value DOWN key It is used to page down and decrease variable value Setting key Used to enter the setting interface SCENARIO mode Click to enter the Scenario mode selection interface COOLING symbol It will display during cooling there is no limit to start up shutdown and it is optional when the unit is cooling only unit or heating and cooling unit HEATING symbol It will display durin...

Страница 17: ... the main display area displays the water inlet temperature the light is on SETTING symbol When the parameter is adjustable it is on FAULT symbol In case of unit fault it is on SCENARIO symbol Flashes in Settings and turns off when you return to the home screen 4 2 Start up Shutdown Start up shutdown operation can only be conducted in the main interface When it displays full screen off click any k...

Страница 18: ...e When the unit is under the defrosting state the defrosting symbol is on with the display interface as follows Notes During the defrosting mode switch is available And when switching the mode the unit won t work under a new mode until defrosting is completed Short press to switch the mode circularly after no operation for 2s the current mode will be saved Automatic mode Heating mode Cooling mode ...

Страница 19: ...tting interface if short press the system will return to the main interface without any changes saved If there is no operation for 5s the system will automatically memorize user s setting and return to the main interface Short press or for entering temperature setting interface Setting temperature flashing Short press or for increasing or decreasing target temperature Short press to return and sav...

Страница 20: ...meter Parameter meaning Parameter range V03 Hour bit of timing boot 1 0 23 V04 Minute bit of timing boot 1 10 20 30 40 50 V05 Hour bit of timed shutdown 1 0 23 V06 Minute bit of timed shutdown 1 10 20 30 40 50 Keep long press of for 5s Short press or to circularly display among Parameter V03 V08 Short press for setting hour digit of timing Short press for setting minute digit of timing Short press...

Страница 21: ...d temperature as soon as possible SMART S The unit combines full power with lower speeds as it approaches the desired temperature or maintains the set temperature only at low speeds EKO E The efficiency that is maximum for the unit is about 40 70 of the power AUTO A It combines all previous modes It maintains the ECO mode while maintaining the required temperature If there is a large change in tem...

Страница 22: ...firm with the setting key 4 V01 clock setting V02 minute setting 4 9 Keyboard lock To avoid others misoperation please lock the wire controller after completing the setting Press for entering password setting interface Press or to choice password 025 press it will entering user setting interface Press or select Parameter Groups V Press for entering clock setting interface Press for setting hour bi...

Страница 23: ...ill be lighten after other operations conducted 2 Under the OFF interface locking operation is available and the operation method is the same as locking screen under the ON interface 4 10 Fault interface When the unit fails the wire controller can display the corresponding code according to the fault reason Refer to the fault table for the specific definition of the fault codes For example Keep lo...

Страница 24: ...prompted to standard display view with Mode Scenario current water temperature big number and requested water temperature small number 1 Short press SETTING key and enter into Password interface SETTING 2 Enter password of 025 step by step by pressing UP DOWN key then short press SETTING key and enter into setting interface Enter the digits 0 2 and 5 one by one and confirm with SETTINGS key UP DOW...

Страница 25: ...when compressor When P01 1 the circulation pump will stop in 2 min after compressor off When P01 2 the circulation pump will run at intervals P02 when compressor off Interval P02 min 30 30 0 120min Duration P03 min 3 3 0 30min Advance P04 min 1 1 0 30min Whether to enable water pump filtering P05 0 0 0 no 1 yes Pump filtration start time 1 P06 hour 10 10 0 23h Pump filter off time 1 P07 hour 12 12...

Страница 26: ...low Otherwise contact your service the flow switch may need to be exchanged Anti freezing Protection E07 Water temperature in the titanium exchanger is 4 C Switch the unit to heating mode The error will be reset automatically if water temperature 8 C E07 Water temperature in the titanium exchanger is 4 C Switch the unit to heating mode The error will be reset automatically if water temperature 8 C...

Страница 27: ... feedback open circuit orshort circuit Check whether current return wires connected motor IPM Overcurrent F06 IPM Input current is large Check and adjust the current measurement Inv DC Overvoltage F07 DC bus voltage Dc bus over voltage protection value Check the input voltage measurement Inv DC Less voltage F08 DC bus voltage Dc bus over voltage protection value Check the input voltage measurement...

Страница 28: ...rn F24 Input current is too large Check and adjust the current measurement EEPROM Error Warn F25 MCU error Check whether the chip is damaged Replace the chip V15V over under voltage fault F28 The V15V is overload or undervoltage Check the V15V input voltage in range 13 5v 16 5v or not Parameter list Meaning Default Remarks Refrigeration target temperature set point 27 C Adjustable Heating the targ...

Страница 29: ...ature Low pressure sensor WARNING a If repair or scrap is required please contact authorized service center nearby b Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certificate from an industry accredited assessment authority which authorizes their competence to handle refrigerants safely in accordance with an industry recognized assess...

Страница 30: ...ir or scrap is required please contact authorized service center nearby 5 Do not attempt to work on the equipment by yourself Improper operation may cause danger 6 In case of risking safety inspection must be carried before the maintenance or repairing for heat pumps with R32 gas 7 The area around the unit should be dry clean and well ventilated Clean the side heating exchanger regularly to mainta...

Страница 31: ...installation repairing removing and disposal during which flammable refrigerant can possibly be released to the surrounding space Prior to work taking place the area around the equipment is to be surveyed to make sure that there are no flammable hazards or ignition risks No Smoking signs shall be displayed 16 Ventilated area Ensure that the area is open or that it is adequately ventilated before b...

Страница 32: ...ts are removed safely When transferring refrigerant into cylinders ensure that only appropriate refrigerant recovery cylinders are employed Ensure that the correct number of cylinders for holding the total system charge is available All cylinders to be used are designated for the recovered refrigerant and labelled for that refrigerant i e special cylinders for the recovery of refrigerant Cylinders...

Страница 33: ... by warranty For particular conditions of this warranty in terms of warranty period and subject please refer to your local regulations and or agreement with your distributor reseller or installer Any action resulting in damage of the heat pump property or other damage caused by improper usage of this product or in contrary with this Installation and user manual is excluded from warranty coverage ...

Страница 34: ...I n s t a l l a t i o n a n d u s e r m a n u a l HP 900 1100 1500 BLACK Inverter V e r s i o n 0 1 2 0 2 2 P a g e 3 4 H E A T P U M P M I C R O W E L L H P Notes ...

Страница 35: ...I n s t a l l a t i o n a n d u s e r m a n u a l HP 900 1100 1500 BLACK Inverter V e r s i o n 0 1 2 0 2 2 P a g e 3 5 H E A T P U M P M I C R O W E L L H P Notes ...

Страница 36: ...100 1500 BLACK Inverter V e r s i o n 0 1 2 0 2 2 P a g e 3 6 H E A T P U M P M I C R O W E L L H P Distributed by Manufacturer MICROWELL spol s r o SNP 2018 42 927 01 Sala Slovakia tel 421 31 770 7082 e mail microwell microwell sk w w w m i c r o w e l l e u ...

Отзывы: