DX-4400
– 3G-SDI Text & Graphics Overlay Inserter – User Manual
Page 53 of 125
Parameters
Description of Command Syntax
N=
Sets the default font name used for text strings if none is specified by the text command.
The font name is not verified. The default is
DejaVu Sans
SB=
Sets the default bold setting for text commands if not specified. It takes
YES
or
NO
as
an argument. It accepts the shortest unique argument. The default is
NO
.
SI=
Sets the default italic setting for text commands if not specified. It takes
YES
or
NO
as
an argument. It accepts the shortest unique argument. The default is
NO
.
SU=
Sets the default underline setting for text commands if not specified. It takes
YES
or
NO
as an argument. It accepts the shortest unique argument. The default is
NO
.
SS=
Sets the default strikeout setting for text commands if not specified. It takes
YES
or
NO
as an argument. It accepts the shortest unique argument. The default is
NO
.
SO=
Sets the default overline setting for text commands if not specified. It takes
YES
or
NO
as an argument. It accepts the shortest unique argument. The default is
NO
.
P=
Sets the default text font size for text commands if not specified. It accepts any number
>= 0, the default value is 60.
DB=
Set the default double buffer setting. It takes
YES
or
NO
as an argument. It accepts the
shortest unique argument. The default is
YES
.
IM=
Sets the save to use an in memory copy of the database. When
YES
a copy of the
database is made in memoy. When
NO
the flash database is used. When you set the
value to
YES
the copy is made and the DX-4400 switches to the in memory database.
When you set the value to
NO
the database in memory is copied back to the flash
database. The default is
NO
.
3.12
User Defined Commands
User Defined Commands allow the assigning of Command Strings to the Toggle and DIP Switches. One or more
commands can be assigned to a switch.
To delete all the User Defined Switch assignments from the current Saveset use the following command:
UDRE
3.12.1 Configuring Toggle Switch Functions
The toggle left and toggle right switches can have up to 16 Command strings assigned to them refer to
When the Toggle Switch is activated it increments the Command string index starting from 0 incrementing up to
15 and then wrapping back to 0. On power up, the index always starts at 0.
Table 24: Toggle Switch
– User Defined Command Syntax
Parameters
Function of the Command Syntax
UDTL
– define string commands for Toggle Left switch action
UDTR
– define string commands for Toggle Right switch action
ID=
Identifies the Command String Index. It takes values from 0 to 15.
"Command"
Where Command is the command or commands that will be processed when the Index
Number occurs. NOTE: The quotations around the Command are required.
RESET
Deletes all the user defined strings.
Must be the first and only argument to command.
Содержание DX-4400 Series
Страница 111: ...DX 4400 3G SDI Text Graphics Overlay Inserter User Manual Page 111 of 125 ...
Страница 113: ...DX 4400 3G SDI Text Graphics Overlay Inserter User Manual Page 113 of 125 ...
Страница 115: ...DX 4400 3G SDI Text Graphics Overlay Inserter User Manual Page 115 of 125 ...
Страница 117: ...DX 4400 3G SDI Text Graphics Overlay Inserter User Manual Page 117 of 125 ...
Страница 118: ...DX 4400 3G SDI Text Graphics Overlay Inserter User Manual Page 118 of 125 ...