The data fields have the following attributes:
Attribute
Explanation
title
Title of the data field (for measurement data this is dependent on the site settings)
units
Units of the data field for measurement data (dependent on the site settings)
calc
OPTIONAL
Is only displayed if it is a channel that has been calculated by the sever
12.3.2.1 Example:
<?xml version="1.0"?>
<Result>
<deviceid id="A15D6246F7AEBFAA" stamp="13.2.2013 09:10:05">
<tag>FFFF0005</tag>
<customer title="Customer">A1519985809987EC</customer>
<devsn title="Serial number">010146AF251D04C3</devsn>
<devclass title="Device class">6000</devclass>
<telnr title="Telephone number">+436764006643</telnr>
<devflags title="Device flags">0007</devflags>
<swversion title="Firmware version">0300</swversion>
<modemversion title="Modem version">0300</modemversion>
<osversion title="OS version">07.0430</osversion>
:
:
</geraetid>
<geraetid id="A1526911CF1A42CC" stamp="13.2.2013 09:33:54" >
:
:
</geraetid>
</Result>
12.4 XML import
The XML import is designed to import the data generated or changed via the user interface, created
by the customer, back into the myDataweb server.
l
Only existing measurement data and settings can be changed or new measurement data can
be added. No historical measurement data can be added.
l
It must be ensured that the
stamp
of the data records is always created in ascending order.
Errors can occur if this is not the case.
l
If any settings are changed, it must be ensured that the
stamp
is set to the current date/time.
Otherwise the data are not synchronised with the device.
l
When creating measurement data, the
id="0"
and
<tag>00006000</tag>
(60 representing the
device class) must always be specified.
l
<tag>0</tag>
must always be specified during the deleting process. Historical data (e.g.
measurement data) cannot be deleted.
12.4.1 Transferring data to the myDataweb server
A HTTP post command can be used to transfer a XML file to be imported by the myDataweb server.
102
Rev. 01
Содержание myDatalogNANOamr
Страница 2: ......
Страница 9: ...Chapter 2 Declaration of conformity Chapter 2 Declaration of conformity Rev 01 9 ...
Страница 10: ......
Страница 12: ......
Страница 20: ......
Страница 40: ......
Страница 56: ...9 2 2 4 GPRS SIM tariff Selected SIM tariff 56 Rev 01 ...
Страница 64: ......
Страница 80: ...wire_color1 wire_color4 Specifies the colours of the pair of wires for the meter input read only 80 Rev 01 ...
Страница 106: ......
Страница 112: ......
Страница 122: ......
Страница 123: ...Chapter 17 Document history Chapter 17 Document history Rev Date Changes 01 26 04 2013 First version Rev 01 123 ...
Страница 124: ......