Page 7
Status
Slow Blink
Battery is low
Charging
Steady Light
The Injector is inactive, the AC adapter is present
and the battery pack is being charged at the maximum rate.
Charging
Off
The Injector is inactive and the battery or AC adapter is
not present; or the Injector is active.
Charging
Blinking (once
The Injector is inactive and the AC adapter is present; the
every 10
battery pack is fully charged and the Injector is in trickle
seconds
charge mode.
Circuit
Blinking
Overvoltage condition
Guard,
Pass, Fail,
plus steady
tone
Super I/Super Injector LED Indicators
Indicator
State
Description
Status
Rapid blink
Test in progress
Status
Steady light
Injector waiting for
signal from Scanner
Status
Slow blink
Injector battery low
Pass
Steady light
Test has passed
Fail
Steady light
Test has failed
Fail, plus
Steady light
Overvoltage steady
tone condition
When to Use the Injector
Some measurements require the use of the Injector at the far end of the cable. For other
measurements, the Injector can be connected but its use is optional. The Scanner automatically
detects the presence of and configures the Injector for the measurement to be performed. The
following table outlines when to use the Injector:
Test Connector
(36-pin on Super
I or Mod 8
on Super Injector)
Pass
Indicator
Fail
Indicator
Status
Indicator