background image

29

Double Feed

This function detects when two or
more pages have been fed into the
scanner at the same time, which helps
prevent lost images when scanning
larger batches of documents. The
Double Feed control tab appears only
when the scanner you are using
implements the double feed function
and the current working frame is “Main
Frame”.

Check double feed: This let you enable the scanner to detect double-feeds error
during scanning from the ADF. If checked, two options are provided for selection —
Uniform and Mixed. The default is checked.

Uniform: This option is used for a stack of documents with the same size/dimension
and thickness. If selected, the scanning will stop and a beep sounds when
double-feed errors caused by this factor occur during scanning. The default is
checked when the “Check double feed” option is enabled.

Mixed: This option is used for a stack of documents with the same size/dimension,
but of different thicknesses. If selected, the scanning will stop and a beep sounds
when double-feed errors caused by this factor occur during scanning.

For details on how to remove double-feeds from the tray, refer to the Microtek
Installation and Operation Manual.

3. Press the Add button, then OK. The customized string will be added to the

Format list for selection.

To remove an unwanted customized string, select it from the Format option menu,
then press the Delete button to remove it.

Содержание ArtixScan DI 2010

Страница 1: ......

Страница 2: ...responsibility for the unauthorized use of copyrighted materials To obtain optimal results from the Microtek scanning software and user s manual you should be familiar with such Windows concepts as p...

Страница 3: ...button 10 Scan Scan To Copy OCR button 10 Scan 10 Scan To 11 Copy 12 OCR 13 Toolbar 14 Select Frame tool 14 Pan tool 14 Zoom In tool 14 Zoom Out tool 15 Create Subframe tool 15 Delete Subframe tool 1...

Страница 4: ...Double Feed 29 MICR Magnetic Ink Character Recognition 30 The File Menu 31 Load Settings 31 Save Settings 31 Save Settings to Function Button 31 Load Settings to Function Button 34 The Scanner Menu 35...

Страница 5: ...ning frames ScanWizard DI features full document scanning tools and on screen proofing You may assign different attributes on the subframes and the preview option gives you a quick scan in the preview...

Страница 6: ...of your application then select Microtek ScanWizard DI From Stand alone mode Double click the ScanWizard DI icon on the Windows desktop or choose Start Programs Microtek ScanWizard DI for Windows the...

Страница 7: ...er as a copy OCR Scans a text document converts and saves it in text format Parameters for controlling the frame location settings i e position of coordinates image size and the unit of measurement in...

Страница 8: ...k White in the Scan Type as your image output type Select RGB Color 24 bits to scan the image in color Select Grayscale 8 bits to scan the image in grayscale Select Black White 1 bit to scan the image...

Страница 9: ...done a preview image appears in the preview window At this moment the previewed page is delivered to the document tray from the ADF s document feed tray Load the previewed page along with the paper st...

Страница 10: ...utput type Select RGB Color 24 bits to scan the image in color Select Grayscale 8 bits to scan the image in grayscale Select Black White 1 bit to scan the image in black and white c Select a dimension...

Страница 11: ...quality using the image correction tools 8 Click the Scan or Scan To button to start scanning If ScanWizard DI is launched from an image editing program the scanned image is delivered after the scan t...

Страница 12: ...ur image output resolution 4 Click the Preview button to perform a preliminary view of the entire image When done a preview image appears in the preview window 5 Click the Select Frame tool button to...

Страница 13: ...ge can be saved after the scan to a file opened in an image editing program or sent to a printer Create Subframe tool The Create Subframe tool lets you create a new frame within the enclosed frame lab...

Страница 14: ...ace the Scan button will not be visible To perform the final scan use the Scan function in your ISIS based application The Preview button scans a page based on the settings on the ScanWizard DI contro...

Страница 15: ...mber If unchecked no file serial number is appended to the file name File prefix This edit box lets you enter a root file name Image is the default Start file This edit box lets you enter a starting n...

Страница 16: ...ns are IBM PC and Macintosh default is IBM PC Encoding Four options are provided for file compression If None is selected image quality compression will not be available for adjustment The default is...

Страница 17: ...dit box lets you enter a root file name Document is the default Start file This edit box lets you enter a starting number to be appended to the file name 00001 is the default Save multiple pages as a...

Страница 18: ...or vertically until you have achieved the desired width and height adjustments for the frame Pan tool The Pan tool lets you scroll through a preview image allowing you to move the partial image into v...

Страница 19: ...om the subframe For example when the main frame image type is Photo it is recommended that you set the subframe image type to Text or Line Art To use the Create Subframe tool button 1 Click the Previe...

Страница 20: ...crop is selected the scanner automatically detects the size of the original image crops the full scan frame to fit the image and removes unwanted black borders after the scan Resolution Allows you to...

Страница 21: ...ne art to obtain superior results Rotate Allows you to rotate the image at increments of 90 degrees Rotate options include None CCW 90 degrees 180 degrees CW 90 degrees and Auto deskew If Auto deskew...

Страница 22: ...single colors such as mechanical drawings blueprints or fine line illustrations Text Text image originals can be RGB Color Grayscale or Black White images If your text image original is Black White yo...

Страница 23: ...W H The Image Size shows the dimensions width and height of the selected frame in the preview window To change the dimensions of the selected frame enter the values manually in the width and height e...

Страница 24: ...ty of image correction tools depends on the Scan Type and Attribute of the image RGB Color Grayscale Black and White Line Art Threshold Threshold Threshold Sharpen Sharpen Sharpen Shadow Highlight Sha...

Страница 25: ...ing point between black and white the range is 0 to 255 and the default is 128 Thus gray levels below the Threshold are converted to black while gray levels equal to or above the Threshold are convert...

Страница 26: ...ion The Hue Saturation control applies only to color photo images Hue is the aspect of color that distinguishes one color from another red from green from blue In the RGB color mode hue can be disting...

Страница 27: ...e resolution of the image The higher the resolution the less obvious the effect of certain filters Sharpen and Sharpen More The Sharpen filters increase the contrast of adjacent pixels making images a...

Страница 28: ...s menu 2 Enter a value in the Strength box to specify the degree of the filter s effect The higher the value the stronger the effect of the filter 3 Select a mask size in the Mask Size box This parame...

Страница 29: ...a value that best corresponds to the dot quality of the original in which the moir is to be removed You may use a screen finder to measure the print screen lpi Please contact your local print shop for...

Страница 30: ...ments the endorser function double feeds or MICR function these tabs can be seen in this window otherwise they will not appear Click any of the tabs to view or customize the function settings accordin...

Страница 31: ...mage making them consistent between the preview image and the final scanned image To change the Gamma of an image drag on the Gamma slide bar Dragging the slider to the left decreases intensity draggi...

Страница 32: ...vary depending on the scanner model The default setting is Small Reference serial This edit box lets you specify the initial number for each document during batch scanning the number ranges from 0000...

Страница 33: ...the same size dimension and thickness If selected the scanning will stop and a beep sounds when double feed errors caused by this factor occur during scanning The default is checked when the Check do...

Страница 34: ...on will not work with other scan type settings even if the Magnetic Ink Character Recognition option is enabled Save in This shows the location where the recognized MICR file will be saved If you have...

Страница 35: ...gs Save Settings to Function Button This command lets you save current image settings to any programmable function button on your scanner and applies only to scanners that implement programmable funct...

Страница 36: ...eginning number for a file name 00001 is the default File format This menu box lets you select a file format when a file is saved TIF is the default file format Once the TIF format is selected the sca...

Страница 37: ...ge Current Printer Shows the default printer To change the printer click the Setup button next to the printer name Show printer setting dialog box before scan Check this option if you want to display...

Страница 38: ...s Document00001 rtf Document00002 rtf etc You can change the default root file name to uniquely label your scan jobs OCR Language This refers to the language in which the original text document is wri...

Страница 39: ...frames not just the selected frame When an image is inverted the brightness value of each pixel is converted to the inverse value on the 256 step color values scale For example a pixel in a positive i...

Страница 40: ...frame is created the created frame will be automatically listed in the window Except for the name Main for the main frame all the added subframes will be automatically identified as Sub1 Sub2 etc in s...

Отзывы: