miline FTL10
LED Multifunction Clock
Page 10
microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach
+49 9681 91960-0,
+49 9681 91960-10, [email protected], www.microsyst.de
7.2 Channel Setting Multifunction Sensor (optional)
6 radio channels are provided for communication between the sensor and display.
This allows the operation of up to 6 display systems in the same transmission range.
It may be necessary to synchronize the multifunction sensor with the display.
Please proceed as follows:
Select desired radio channel (01 to
06) with display’s menu item P8.
Open the multi-function light sensor and press the button on the board about 1
second until the green LED is lit.
After synchronisation, this LED goes off and the display will quit setup mode
automatically.
After 20 seconds at the earliest, current data are shown.
7.3 DCF Setting (optional)
You can force an attempt for DCF77 reception with menu item P9 to find the optimal
position for the multifunction sensor.
Please stay in this menu and observe the status message. If the reception is suffi-
cient, you get the following sequence (within max. 5 minutes):
Status message Meaning
0
Attempt for reception started
1
DCF signal identified
2
Data reception
3
Time and date have been updated
The DCF signal is not sufficient, if the status message changes between “1” and “2”.
At status “0”, no reception is possible.