miline FTL10
LED Multifunction Clock
Page 9
microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach
+49 9681 91960-0,
+49 9681 91960-10, [email protected], www.microsyst.de
7.1 Display Settings
Press button
for 2 seconds until
the display’s hour digit starts to flash, then use the
navigation keys to select the desired menu item. The values can be changed with the
corresponding buttons.
Menu Navigation
(button ““):
Hours
Time setting
For systems with multi-function sensor,
DCF77 defaults always take precedence.
Minutes
Day
Date setting
For systems with multi-function sensor,
DCF77 defaults always take precedence.
Month
P1 - Display time
Appearance of the single measures:
00: deactivated
01: activated
Standard without „MFS10“: P1 + P2 = 01
P3 + P4 = 00
Standard with „MFS10“:
P1...P4 = 01
P2 - Display date
P3 - Display temperature
(optional with “MFS10”)
P4 - Display humidity
(optional with “MFS10”)
P5 - Alternation interval
Time for displaying a measure.
Setting range: 01 to 30 seconds
Standard: 05
P6 - Maximum brightness
This menu item is shown with the current maxi-
mum brightness.
Setting range: 01 to 99
Standard: 99
P7 - Flashing colon (at the time)
Setting range: 00 / 01
00: deactivated
01: activated
Standard: 01
P8 - Radio channel
Selection of the radio channel
Setting range: 01 to 06
Standard: 01
P9 - Request DCF77 reception
DCF77 status
(description see next page)
The settings are saved with the button
. After that, setup mode is left.