3.7.6 Macros
Macros are predefined command sequences included in the device
configuration.
They are analogous to the data units in the online frames.
The first macro line is executed after the device is switched on (if one
exists). Subsequent macro lines are executed every 100 ms. A macro
line can consist of several commands. Macro execution is stopped after
the last macro line has been executed.
3.7.6.1 Start Macro Execution
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
ESC
Function
Macro no.
hundreds
Macro no.
tens
Macro no.
ones
1B
h
“M”
“0” – “9”
“0” – “9”
“0” – “9”
Execution starts with the indicated macro.
Skipping is also possible during macro execution through the use of this
command within a macro sequence.