3.10.1 Online Texts
Online texts are transmitted without an escape sequence (ASCII codes
20
H
– FF
H
, 0A
H
, 0D
H
)
.
Transmitted ASCII characters are displayed with the current character
set at the current cursor position in consideration of current attributes.
Line breaks are accomplished with the help of ASCII code 0A
H
or 0D
H
by
transmitting the escape sequence for setting cursor position (ESC-
“C”).
If the display limits are exceeded, read-out is continued at the next line,
or at the first line of the display unit.
3.10.1.1 Selecting a Character Set
Byte 1
Byte 2
Byte 3
Byte 4
ESC
Function
Character set no.
tens
Character set no.
ones
1B
h
“Z”: normal character width
“z”: uniform character width
“0” – “9”
“0” – “9”
Three character sets are included with the display unit upon delivery:
50 mm (1.97’’) character set (character set “Z00”, “z00”)
75 mm
(2.95’’) character set (character set “Z01”, “z01”)
100 mm (3.94’’) character set (character set “Z02”, “z02”).
Existing character sets are overwritten with the new character sets if a
new configuration is downloaded to the display unit!