CAN termination on the CRX-S32G carrier.
Figure 6-6 CAN Termination
C
AN termination and CAN protection are referenced to Shield
CRX-S32G-R3
V1
Ax has CAN-termination on carrier as described in above
schematic.
CRX-S32G-R3
V2
Ax has
NO
CAN-Termination on carrier. Resistors (2x 60R4) are