Technical Description
miriac MPX-LX2160A User Manual
V1.4
61/73
© MicroSys Electronics GmbH 2020
4.21.5
ME USB
Available on request, custom modifications can be implemented.
4.21.6
ME Power Control
Available on request, custom modifications can be implemented.
4.22
CPLD Interfaces
Available on request, custom modifications can be implemented.
4.23
Fan
The fans are controlled by the management controller depending on the board
temperature. There are 2 independent channels on the module, each controlled by
a MAX31790 fan controller. Fans may be connected to ST5 and ST6 (one each).