5
products;
The pressure interface of the conventional pressure transmitter is
M20×1.5 with sealing gasket
;
To facilitate installation and maintenance
,
a globe valve should be installed between the flange joint and the pipe,to
see figure 1.
Pressure Transmitter
Valve
Pipe
Figure 1
3.2.2.2 recommended installation method of liquid level
products:
Installation in Static Water
a)
The installation method in the pool to see Figure 2.To protect the
transmitter, it should be mounted far away from the pumping in/out
source to prevent the pumping impact; the transmitter also could
be mounted as Figure 3, protected by steel pipe.
b)
The installation method in the deep well to see Figure 3.Steel pipe
inserting method could be used. The steel pipe could not be bent,
the internal diameter
>
30mm. Several little holes could be made at