Microsens MS450154PM-48 Скачать руководство пользователя страница 5

Installation-Switch 45x45 with TP-Uplink 

 Page 

5/6 

MICROSENS

 GmbH & Co. KG - Kueferstraße 16 - D-59067 Hamm / Germany - Tel. +49 23 81/94 52-0 - FAX -100 - www.microsens.com 

 

  Resetting of the Switch 

 

It is possible to reset the Switch by using the two buttons, which are integrated in the RJ45 
sockets of the ports 1 and 2. 
 
The buttons have following functions: 
 

 

 

 

Reset Factory Default

Reset / IP Confuguration

 

 

Fig.. 3: Position of the reset buttons 

 
 

1. Reset / IP-Configuration 

Reset: 

The switch can be reset by short pressing of the relevant button. Then the last stored 
configuration is loaded into the unit. The Management configuration such as IP address and unit 
name is not changed. 

Attention: During the reset the data transmission via the switch is interrupted 
 

IP-Configuration: 

Longer pressing  (approx. 5 sec) of the relevant button causes the IP Configuration after the 
done reset. Now the IP address and the unit name can be given in via a network computer with 
started Device Manager Software.   

 

 

2. Factory Reset 

By continuously pressing of the relevant factory reset button while activity of the reset button 
(port 1) all in the unit stored configuration settings are reset to factory adjustments. The 
configuration of the agent like IP address and unit name will not be changed. 

The “factory reset” is only relevant for the switch data, not for the integrated management 
agent. Only port configurations, priorities and VLAN settings will be reset.  

 