Installation-Switch 45x45 with TP-Uplink
Page
3/6
MICROSENS
GmbH & Co. KG - Kueferstraße 16 - D-59067 Hamm / Germany - Tel. +49 23 81/94 52-0 - FAX -100 - www.microsens.com
Technical Specifications
Type
Fast Ethernet Installation-Switch 45x45
5 Ports 10/100Base-TX according IEEE 802.3
for cable trunk/sub floor box mounting
Cable type
STP-cable, 100
Ω
, Category 5 with RJ-45 connector
Max. cable length
100 m
Data rate
10
or
100
Mbps
LED displays
ON
Ready for operation
L0
on:
Link at Uplink-Port
flashing:
Data transmitted on uplink port
FD
off:
Uplink connection half duplex
mode
flashing:
Collision in half duplex mode
on:
Uplink full duplex
each TP-Port 1..4:
Ln
on:
Link at Port
n
flashing:
Data transmitted on Port
n
Power Supply
Direct –current voltage 48 VDC (44 to 55 V DC)
max. 3.5 W for switch plus max. 4x 15.4 W
for the supply of connected end devices (PD)
Operating temperature
0°C to 50°C
Storage temperature
-20°C to 85°C
Rel. humidity
5% to 80% non condensing
PoE
optional (only MS450154PM-48 version)
Integrated controller according IEEE 802.3af:
- max. 15.4 W per port (by using an external power supply)
- max. 10 W total (in operation mode as Powered Device)