CLI Commands
30
098-00777-000 Rev. A
show alarm-config:
Displays the alarm configuration including alarm ID, severity, state, reporting delay and description for
S80 alarms. This also displays if the alarm is transitory.
Command Syntax:
show alarm-config
Level:
User, Config and Admin
Example:
S80> show alarm-config
Response:
ID Severity State Delay Event/Alarm Descriptions
1 Minor enable 0 "Entered time/frequency warm-up state"
2 Minor enable 0 "Entered time/frequency free-run state"
3 Event enable 0 "Entered time/frequency fast-track state"
4 Event enable 0 "Entered time/frequency normal-track state"
5 Event enable 0 "Entered time/frequency bridging state"
6 Minor enable 0 "Entered time/frequency holdover state"
8 Minor enable 0 "Entered time/frequency holdover rec state"
21 Minor enable 0 "GNSS input assessing"
22 Event enable 0 "GNSS input time qualified"
23 Event enable 0 "GNSS input freq qualified"
24 Event enable 0 "GNSS input selected as time reference"
25 Event enable 0 "GNSS input sel as freq ref"
51 Minor enable 0 "Incompatible transport type"
91 Minor enable 0 "GNSS receiver communications failed"
92 Minor enable 0 "GNSS receiver not tracking satellite"
98 Event enable 0 "GNSS PPS failed"
99 Event enable 0 "GNSS Base Config failed"
111 Minor enable 0 "Ethernet port link down"
112 Minor enable 0 "Excessive traffic on port ETH"
137 Critical enable 0 "PLL synthesizer unlock"
139 Minor enable 0 "Temperature out of range"
152 Event enable 0 "Timeline has been changed"
153 Event enable 0 "Phase has been aligned"
155 Event enable 0 "System reboot"
156 Event enable 0 "Ethernet speed"
157 Event enable 0 "Gnss acquisition status"
179 Event enable 0 "NTP Stratum Change"
180 Event enable 0 "NTP Leap Change"
181 Event enable 0 "NTP Passive mode"
182 Event enable 0 "NTP Active mode"
183 Event enable 0 "NTP Service load limit"
set alarm-config:
Use this command to provision the alarm state, alarm level, and reporting delay time for the specified
alarms. The reporting delay time is the amount of time from when the alarm occurred to when it is
reported. The delay parameter will delay the reporting of an alarm by the configured amount.
Command Syntax:
•
To provision the state of the specified alarm number:
set alarm-config state {alarm [1 to 163] | all} {enable | disable}
•
To provision the level of the specified Alarm number:
set alarm-config level {alarm [1 to 163] | all} {2 |3 | 4 | 5}
Where:
– 2 - Critical
– 3 - Major
Содержание SyncServer S80
Страница 1: ...SyncServer S80 NTP Server User Guide Part Number 098 00777 000 Revision A...
Страница 2: ...SyncServer S80 NTP Server...
Страница 6: ...SyncServer S80 NTP User Guide 098 00777 000 Rev A 6...
Страница 10: ...Installation of SyncServer S80 10 098 00777 000 Rev A Figure 2 1 SyncServer S80 Connection Diagram...
Страница 18: ...Installation of SyncServer S80 18 098 00777 000 Rev A Figure 2 8 Installation Bracket for SyncServer S80...
Страница 19: ...SyncServer S80 NTP User Guide 098 00777 000 Rev A 19 Figure 2 9 Cable Routing Before Final Assembly...
Страница 21: ...SyncServer S80 NTP User Guide 098 00777 000 Rev A 21 Figure 2 11 Attaching SyncServer S80 to Pole...
Страница 22: ...Installation of SyncServer S80 22 098 00777 000 Rev A Figure 2 12 Attaching SyncServer S80 and Pole to Bracket...
Страница 24: ...Installation of SyncServer S80 24 098 00777 000 Rev A Figure 2 15 Surge Protector Dimensions...
Страница 25: ...SyncServer S80 NTP User Guide 098 00777 000 Rev A 25 Figure 2 16 Connecting Surge Protector...
Страница 50: ...CLI Commands 50 098 00777 000 Rev A...
Страница 60: ...Configuration 60 098 00777 000 Rev A...