Timing Status & Information
The Timing window in the dashboard, as shown in
, displays status
details and information about system timing, including current reference, lock
status, and status of input references. See
Figure 4-4.
Timing Window
Note:
The SyncServer 6x0 does not contain a battery-backed
real time clock. Therefore, it will always boot up with a default
value for the system time. This time will be updated when it
obtains time from a time reference such as GNSS, IRIG, or
NTP. The default value for the date is the software build date.
This date will be used for the first log entries when booting up
the unit. The time will change to local time during the boot-up
process if a time zone has been configured.