"DATA" and "DATA & POWER" ports of the Power over
Ethernet Midspan are shielded RJ-45 data sockets. They
cannot be used as Plain Old Telephone Service (POTS)
sockets. Only connect RJ-45 data connectors to these
sockets.
Associated Ethernet wiring shall be limited to
the
inside
of the building.
2.3 Power Cord
In case power cord is replaced, replacement must meet local
requirements.
To ensure a reliable connection to an AC mains supply,
equipment provides an appliance IEC60320 inlet used for
connecting a detachable power supply cord.
Power socket outlet must be located near Midspan and
easily accessible.
The only way of removing power from
unit is by disconnecting the power cord from the outlet
This unit operates under SELV (Safety Extra Low
Voltage) conditions, according to EN60950-1/IEC60950-
1. Conditions are maintained only if the equipment to
which unit is connected also operates under SELV
conditions.
2.4
Power Cord Specifications by Country
U.S.A. and
Canada
Cord must be UL-approved or CSA certified.
Minimum specification for flexible cord is:
o
No. 18 AWG
o
Type SV or SJ
o
Three-conductor
Cord set must have a rated current capacity
of at least 13A for PD-9612G/ACDC/M, PD-
9606G/ACDC/M;
Attachment plug must be an earth-grounding
type with a NEMA 5-15P (15A, 125V) or
NEMA 6-15P (15A, 250V) configuration.