DOC 6501_Release V
ATS-6501 Users Guide
113
ATS-6501>status health:over_temperature
[active] false
[occurrences] 0
The ATS-6501 monitors the fans on the front panel to ensure they are operating, to check the
current status of the fans use the
status hardware:fan
command. Both fans should show a status
of 1 indicating it is operating normally.
ATS-6501>status hardware:fan
[1] true
[2] true
Users can look to see if the unit had any issues with either of the fans by using the
status
health:fan
command
ATS-6501>status health:fan
[1]
[active] false
[occurrences] 0
[2]
[active] false
[occurrences] 0
Note:
If the unit is reporting an over temperature condition and the fans are not reporting an
error, ensure the ambient temperature is less than 65ºC and the fan filters are clean.
6.2.9 PPS Outputs
The ATS-6501 is capable of providing different PPS outputs on each port of the 4394A/4376A
cards and on ports 1 and 2 of the 4394A-ECL card. By default the 1PPS signal is a 100 µs wide
pulse. Users can modify these settings. Users are cautioned to ensure they connect the correct
cables to the correct output ports to avoid any problems.
To verify the settings use the
settings hardware:slots:N
command (where N=Card Slot #) to
verify the system settings.
ATS-6501> settings hardware:slots:1
[tsc4373]
[ports]
[1]
[pps_period] 1
[pps_width] 1.000000000000000e-04
[type] pps
[2]
[pps_period] 1
[pps_width] 1.000000000000000e-04
[type] pps
[3]
[format] B
[signal_word] 0
[type] irig
[4]
[format] B
[signal_word] 0
[type] irig
Содержание ATS-6501 T-Flex
Страница 2: ......
Страница 103: ...DOC 6501_Release V ATS 6501 Users Guide 95 ...
Страница 222: ...DOC 6501_Release V ATS 6501 Users Guide 214 Appendix I Certificate of Compliance ...