DOC 6501_Release V
ATS-6501 Users Guide
112
6.2.6 NTP Server
The NTP locked indicator will be green when the NTP server is capable of providing time within
specifications to other systems on the network. When the NTP Server is operating outside of its
specification the indicator will be out. To look at the current status of the internal NTP Server use
the
status reference:ntp
command. If the NTP Server is operating properly the user will see the
following:
ATS-6501>status reference:ntp
[locked] true
[source] internal refclock
[OK] 2013-08-08T15:01:03Z
6.2.7. PTD Value is Noisy
The PTD (UTC Offset) value will be much noisier when the ATS-6501 is in the dynamic mode
and during the positioning period while in the AUTO mode.
•
Static position users should use the AUTO mode when the antenna position is unknown.
After the auto_hours has expired, the antenna position will be determined by the receiver
and the ATS-6501 will switch to the fixed position mode. Once this happens, the PTD
value will be significantly quieter. Users should put the system in Manual positioning
mode and save settings once AUTO mode is complete in order to prevent AUTO mode
from occurring after a power failure.
•
If the antenna position is known, users should put the system in Manual positioning mode
and enter the latitude, longitude, and altitude of the antenna.
•
Poor antenna location and/or multipath issues can cause instabilities, relocate the antenna
to a more suitable location.
ATS-6501>settings gps
[antenna_delay] 0.00000000000
[antenna_voltage] 0.00000000000
[datum] wgs84
[mask_angle] 1.00000000001
[positioning]
[auto_hours] 1.20000000001
[manual_position]
[altitude] 1.59272900003
[latitude] 4.00194142201
[longitude] -1.05239096202
[mode] auto
6.2.8 Over Temperature and Fans
The ATS 6501 monitors the internal temperature will trigger an alarm to be displayed on the front
panel and the
status alarm
list when the internal temperature reaches or exceeds 65ºC. To check
the current temperature on the system use the
status hardware:temperature
command.
ATS-6501>status hardware:temperature
31
Users can look to see if the unit had any temperature issues by using the
status
health:over_temperature
command