Copyright
2017
Microsemi
Page 14
PD-9501GO-ET
One Enterprise Aliso Viejo, CA 92656 USA
Safety Information
Installation and removal of the PoE Midspan must be carried out by
qualified personnel only.
The PoE Midspan "DATA IN" and "DATA PWR OUT" ports are
shielded RJ45 data sockets. They cannot be used as Plain Old
Telephone Service (POTS) sockets. Only RJ45 data connectors
can be connected to these sockets.
Read the installation instructions before connecting the PoE
Midspan to its power source.
Follow basic electricity safety measures whenever connecting the
PoE Midspan to its power source.
A voltage mismatch can cause equipment damage and may pose a
fire hazard. If the voltage indicated on the label is different from the
power outlet voltage, do not connect the PoE Midspan to this power
outlet!
All wiring and connections shall be in accordance with NFPA 70
(NEC)
This product is not intended to become a permanent part of the
building structure.
Power supply cord must not be attached to the building surface or
run through walls, ceilings, floors and similar openings in the
building structure.
Measures must be taken to prevent physical damage to the power
supply cord, including proper routing.