background image

Functions and Features 

 

The Microsemi 9002GHO 2-Port 802.3at 
Gigabit PoE Outdoor Hub Midspan injects 
power over data-carrying Ethernet cabling. 
It maintains IEEE802.3at and IEEE802.3af 
standards. These power levels allow 
usage by a new range of Ethernet-based 
applications such as video phones, 
802.11n Access Points, WiMAX 
Transmitters, PTZ cameras and more. PD-
9002GHO 

DATA PWR OUT

 port is 

designed to carry Gigabit Ethernet data & 
power over a standard CAT5e/ 6 cable, 
delivered through 4-pairs by 

DATA PWR

 

OUT1 

(Alt A: pins 1,2 (-) / 3,6(+)) and by 

DATA PWR OUT2

 (Alt B: pins 4,5 (+) / 7,8 

(-)).  

 
 

PD-9002GHO EMC Compliance:  

 

CE: 

o

  EN55024, EN61000-4-5  

o

  EN55022 class B 

 

FCC Part 15 class B 

 

VCCI 

 

PD-9002GHO Safety 
Compliance

:  

 

UL60950-1 for  
PD-9002GHO/AC-NA 

 

GS mark for  
PD-9002GHO/AC-INTL  

 

EN60950-22 

PD-9002GHO Lightning 
Protection

:  

 

Designed 

to 

meet 

GR-1089-

CORE 

lightning 

protection 

demands 

Other Standards and Approvals: 

 

IEEE  802.3at  &  IEEE  802.3af 
(PoE) standards 

 

RoHS Compliant 

 

Compliance WEEE 

 

Dust & Water Intrusion 

o

  EN60529, level IP66 

 

o

  NEMA 250, level 4x 

 

ASTM B-117 corrosion resistance 

Preliminary Steps 

 

Earth 

terminal 

should 

be 

connected 

before 

mains 

are 

connected 

 

Ensure AC power is applied to the 
PoE Midspan. 

 

Ensure output Ethernet cables are 
connected  to  DATA  PWR  OUT 
ports. 

 

Verify 

power 

ready 

Ethernet 

compatible device is connected. 

 

Installation 

PoE Hub Midspan can be placed on a 
desktop or mounted on a wall/bench (all 
kind of flat surfaces: wood, brick, 
concrete etc.) using the mounting holes. 

Note: 

Before mounting PoE Hub 

Midspan to a fixed location: 

 

Ensure  cable  length  from  Ethernet 
network source to the terminal does not 
exceed  100  meters  (333  feet).  PoE  is 
not  a  repeater  and  does  not  amplify 
Ethernet data signal. 
Use  a  splitter  if  desired;  ensure  splitter 
is  connected  close  to  the  terminal  and 
not on the Midspan!  

 

PoE Hub MIdspan AC power plug shall 
be  connected  to  a  sealed  box  in  order 
to meet EN60529 level IP66 and NEMA 
250 level 4x. 

PoE  MIdspan  AC  power  lines  shall  be 
connected to the socket-outlet that shall 
be  installed  near  the  equipment  and 
shall be easily accessible 

Funktionen und Eigenschaften 

 

Die Microsemi 9002GHO 2-Anschluss 802.3at 
Gigabit PoE Außennabe Midspan speist Strom 
über datentragenden Ethernet Verkabelung. 
Sie entsprechen den IEEE802.3at und 
IEEE802.3af Normen. Diese Leistungsstufen 
ermöglichen den Einsatz durch ein neues 
Angebot von Ethernet-basierte Anwendungen 
sowie 802.11n Videotelefon Zugangspunkten, 
WiMAX Sendern, PTZ Kameras und mehr. Der 
PD-9002GHO 

DATA PWR OUT

 Anschluss ist 

vorgesehen, Gigabit Ethernet Daten & Strom 
über einem CAT5e/ 6 Standardkabel zu 
tragen, die durch 4-Paaren durch 

DATA PWR

 

OUT1

 (Alt A: Stecker 1,2 (-) / 3,6(+) und durch 

DATA PWR OUT2

 (Alt B: Stecker 4,5 (+) / 7,8 

(-)) abzugeben.  

PD-9002GHO EMC Einhaltung:  

 

CE: 

o

  EN55024, EN61000-4-5  

o

  EN55022 B-Klasse 

 

FCC Part 15 B-Klasse 

 

VCCI 

Einhaltung der PD-9002GHO 
Sicherheitsvorschriften

:  

 

UL60950-1 fur PD-9002GHO/AC-NA 

 

GS Marke fur  
PD-9002GHO/AC-INTL  

 

EN60950-22 

PD-9002GHO Blitzschutz

:  

 

Vorgesehen  den  GR-1089-CORE 
Blitzschutzanforderungen 
nachzukommen. 

Andere Normen und Zulassungen: 

 

IEEE  802.3at  &  IEEE  802.3af  (PoE) 
Normen. 

 

RoHS konform 

 

Einhaltung WEEE 

 

Staub- und Wassereindringen 

o

  EN60529, Stufe IP66 

 

o

  NEMA 250, Stufe 4x 

 

ASTM 

B-117 

Korrosionsbeständigkeit 

Vorläufige Schritte 

 

Masseklemme 

soll 

vor 

dem 

Netzanschluss 

angeschlossen 

werden. 

 

Stellen 

Sie 

sicher, 

dass 

die 

Spannungsversorgung 

des 

PoE 

Midspan hergestellt ist. 

 

Stellen  Sie  sicher,  dass  die  Ethernet 
Ausgangskabel  an  den  DATA  PWR 
OUT  Anschlüssen  angeschlossen 
sind. 

 

Überprüfen 

Sie, 

dass 

ein 

Leistungsbereite  kompatibles  Gerät 
angeschlossen ist. 
 

Installierung 

PoE Hub Midspan kann durch Verwendung 
der Montagebohrungen auf einem Tisch 
gestellt oder an einer Wand/Bank montiert 
werden (glatte Oberflächen aller Arten: 
Holz, Ziegel, Beton usw.) 

Hinweis: 

Vor der Montierung des PoE Hub 

Midspan an einem festen Standort: 

 

Stellen  Sie  sicher,  dass  die  Länge  des 
Kabels von der Ethernet Netzquelle bis zur 
Klemme  nicht  mehr  als  100  Meter  (333 
Fuß)  beträgt.  PoE  ist  kein  Repeater 
verstärkt das Ethernet Datensignal nicht 
Verwenden 

Sie 

auf 

Wunsch 

einen 

Leitungsteiler;  Stellen  Sie  sicher,  dass  der 
Leitungsteiler neben der Klemme und nicht 
an das Midpsan angeschlossen ist! 

 

PoE Hub Midspan Netzstecker soll an eine 
verschlossene  Schachtel  angeschlossen 
werden,  um  die  EN60529  Stufe  IP66  und 
NEMA 250 Stufe 4x zu entsprechen. 
PoE Midspan Wechselspannungsleitungen 
an eine Steckdose angeschlossen werden, 
die 

si

ch

 in 

Gerätenähe befinden und leicht 

zugänglich sein sollte.

 

           Mounting Instructions  /  Einbau des Gerätes 

Product View /  Produktansicht 

 

EARTH GROUND

  

DATA PWR1 DATA PWR 2

LINE AC

 

Step  1:

  Fasten  the  PD-9002GHO  using  three  screws  (screw  holes  are 

markert 1,2,3)

 

Schritt  1:  Befestigen  Sie  den  PoE  Midspan  mit  drei  Schrauben  gemäß 
Abbildung 1 (die Schraubenlöcher sind mit 1, 2, 3 markiert)  

 

46.36mm

 

1

9

6

m

m

1

2

3

 

          

Step 2:

 Connect the chassis bolt to earth ground 

            Schritt 2:

 

Verbinden Sie den Schraubenbolzen mit der Erde  

 

Step 2.1: Tighten Nut 2  while 
preventing rotation of Nut 1.

Schritt 2.1: Schnallen Sie  
Schraube 2 an ohne dass 
Schraube1 sich dreht.

Step 2.2: Apply between 

Verwenden Sie 

für Schraube 2 ein 
Drehmoment zwischen 

NUT 1 

NUT 2 

Connect to earth ground
Eine Verbindung mit der 
Erde herstellen

10in.- lb (1.1 Nm) and 
15in.- lb (1.7 Nm) of torque 

to Nut 2.

Schritt 2.2:

10in.- lb (1.1 Nm) und15in.- lb (1.7 Nm).  

 

           
 
           

Step 3:

 Ethernet RJ45 Cable Assembly 

  

Schritt 3:Montage des Ethernet RJ45-Kabels 

 

STEP 4

STEP 1

FASTEN TIGHTLY BY HAND

STEP 3

STEP 6

FASTEN TIGHTLY BY HAND

STEP 2

STEP 5

 

Step 4: Connect 

DATA 

PWR OUT1

 jack to the 

terminal1 and 

DATA PWR 

OUT2

 jack to the terminal2 

 
Step 5: Connect the PoE 
Injector to an AC power 
line (100-240VAC) (via a 
readily accessible 
disconnect device) 
For more details on installation of the 
unit on a pole 

– see mount kit 

installation guide 

  

Notes: 

  Do not use cross over cable 

between PoE Hub Midspan output 
port and load device 

  Two RJ45 male plug waterproof 

connectors covers are supplied 
with the unit. 

  Ethernet cable and RJ45 male 

connectors are not supplied with 
the unit. 

  The product is designed for outdoor 

use. 

 

Schritt 4: Schließen Sie die  

DATA PWR OUT1

 Buchse an  

Klemme 1 an und die  

DATA PWR OUT2

 Klemme an  

Klemme 2 an.X 

Schritt 5: Schließen Sie den PoE-

Midspan an das Stromnetz an (100-
240VAC) (über ein leicht 
zugängliches nicht angeschlossenes 
Gerät) 
Im Benutzerhandbuch des 
Montagenkits finden Sie die weiteren 
Details wie das Gerät am Pfahl zu 
installieren ist 

Hinweise: 

  Verwenden Sie keine Cross-Kabel 

zwischen dem Ausgangsanschluss 
des PoE Nabe Midspan und dem 
Ladengerät. 

  Zwei wasserdichte Abdeckungen 

für die RJ45-Stecker werden mit 
dem Gerät mitgeliefert. 

  Ethernet-Kabel und RJ45-Stecker 

sind nicht im Lieferumfang des 
Gerätes inbegriffen 

  Dieses Produkt ist für 

Außenanwendung vorgesehen 

 

Troubleshooting 

Fehlersuche 

Symptom 

Corrective Steps 

Abhilfemaßnahmen

 

Midspan does 
not power up 

Midspan startet 
nicht

 

 
1.  Verify a reliable power cord is 
used. 
2.  Verify voltage at the power 
inlet is between 100-240 V

ac

3.  Remove and reapply power to 
the device and check the 
indicators during power up 
sequence. 

 
1. Überprüfen Sie, dass eine 
zuverlässige Anschlussleitung 
verwendet wird. 
2.  Überprüfen Sie, dass die 
Spannung am Netzeingang 
zwischen 100-240 
Wechselspannung liegt. 
3.  Schalten Sie das Gerät aus 
und dann schalten Sie es wieder 
ein und  überprüfen Sie die 
Anzeigen während des 
Startvorganges. 

The PD does not 
operate 

 

Das PD 
funktioniert nicht

 

 
1.  Verify the Midspan detects a 
PD. 
2.   Verify PD is designed for PoE 
operation. 
3.  Verify you are using a standard 
Category 5/5e/6, straight-wired 
cable, with four pairs. 
4.  If an external power splitter is 
in use, replace it with a splitter 
known as good. 
5.  Ensure input Ethernet cable is 
connected to the Data In port. 
6.  Verify PD is connected to the 
Data & Power port.  
7.  Try to reconnect the same PD 
into a different Midspan. If it 
works, there is probably a faulty 
port or RJ45 connection. 
8.  Verify there is no short over 
any of the twisted pair cables or 
over the RJ45 connectors. 

 
1.  Überprüfen Sie, dass das 
Midspan ein PD erkennt. 
2.   Überprüfen Sie, dass das PD 
für PoE Betrieb vorgesehen ist. 
3.  Stellen Sie sicher, dass Sie ein 
standardmäßiges 5/5e/6 
4.  Wenn eine äußere 
Leitungsteiler im Einsatz ist, 
ersetzen ihn durch einen 
betriebsfähige Leitungsteiler. 
5. Stellen Sie sicher, dass das 
Ethernet-Eingangskabel am DATA 
IN Port angeschlossen ist. 
6.  Überprüfen Sie, dass das PD 
am DATA / POWER Port 
angeschlossen ist. 
7.  Versuchen Sie dasselbe PD 
mit einem anderen Midspan zu 
verbinden. Sollte es klappen, 
dann geht es wahrscheinlich um 
einen fehlerhaften Port oder RJ45 
Anschluss. 
8.  Überprüfen Sie, dass es 
keinen Kurzschluss über einem 
der RJ45 Steckverbinder gibt. 

The end device 
operates, but 
there is no data 
link 

 

Das Endgerät 
funktioniert, aber 
es besteht keine 
Datenverbindung
.

 

 
1.  Verify the port indicator on the 
front panel is continuously lit. 
2.  If an external power splitter is 
in use, replace it with a known-
good splitter. 
3.  Verify that for this link, you are 
using standard UTP/FTP 
Category 5 straight (non-
crossover) cabling, with all four 
pairs. 
4.  Verify Ethernet cable length is 
less than 100 meters from 
Ethernet source to load/remote 
terminal. 
5.  Try to reconnect the same PD 
into a different Midspan. If it 
works, there is probably a faulty 
port or RJ45 connection. 

 
1.  Stellen Sie sicher, dass die 
Port-Anzeige auf der Frontpalette  
2.  Wenn eine äußere 
Leitungsteiler im Einsatz ist, 
ersetzen ihn durch einen 
betriebsfähige Leitungsteiler. 
3. Stellen Sie sicher, dass Sie für 
diese Verbindung standardmäßige 
UTP/FTP Kategorie 5 gerade 
Verkabelung (ungekreuzt) 
verwenden.  
4. Überprüfen Sie dass die 
Kabellänge von der Ethernet 
Quelle bis zum 
Ladengerät/entlegenem Gerät 
weniger als 100 Meter beträgt. 
5. .  Versuchen Sie dasselbe PD 
mit einem anderen Midspan zu 
verbinden. Sollte es klappen, 
dann geht es wahrscheinlich um 
einen fehlerhaften Port oder RJ45 
Anschluss. 

 

 