Chapter 3
Communications
MS-710 Scanner User’s Manual
3-21
3–Communica
ti
ons
Intercharacter Delay
Usage:
Used only when a host cannot receive data quickly enough and there is
enough time between symbols to allow data to be completely transferred.
It is rarely used since any setting other than zero will slow down commu-
nications. For example, a 200 setting will result in a 1/5 second delay
between each character that is transmitted.
Definition:
The time interval in milliseconds between individual characters transmit-
ted from the scanner to the host.
Serial Cmd:
<
KB
intercharacter delay>
Default:
0
Options:
0 to 255 (in milliseconds). Zero (0) causes no delay between
characters.