ENGLISH
Operation
User interface - Control panel
See Fig. 1
1. Control panel
2. Alarm indicator (red)
3. Charging indicators (green and yellow)
4. Mains power indicator (blue)
5. Multifunction buttons
6. STOP button
7. Radio indicator (green)
Charging
Warning
High voltage!
If there is evidence of damage to the battery
charger, cables or connectors, switch off the mains
power. Do not touch damaged parts.
Do not touch uninsulated battery terminals,
connectors or other live electrical parts.
Contact service technician.
Connecting the battery
1. Check the cables and connectors for visible
damage.
2. Check that there is mains power to the charger,
see Fig. 1 pos 4.
3. Connect the battery charger to the battery.
• The battery charger automatically starts
charging when the battery is connected.
• The charging status is shown on the control
panel by the charging indicators. See
Indicator status on the Control panel
• A green battery symbol is lit when the
battery is fully charged, see Fig. 1 pos 3.
The battery charger continues with
maintenance charging.
• The battery can be continuously connected
to the battery charger when not in use.
Note:
The green battery symbol might not be lit up
immediately if a fully charged battery is connected.
The delay time can be up to several hours.
Disconnecting the battery
Warning
Risk of explosion!
Do not disconnect the battery charger while the
charging process is in progress. Sparks may be
generated that can damage the charging
connector, and for lead acid batteries this can
cause a hydrogen explosion.
Always stop the charging process by pressing the
STOP
button before the battery is disconnected.
1. Stop the battery charging process by pressing
the
STOP
button on the battery charger control
panel.
The charging process can be resumed by
pressing the
STOP
button again.
2. While stopped disconnect the battery charger
from the battery.
Parameter settings
Caution
Incorrect charging parameters can damage the
battery.
Always check the charging parameters prior to
start of charging.
Edit and check charging
parameters
1. Disconnect the mains power to the charger and
disconnect the battery.
2. Connect the charger to the mains power.
Mains indicator lights up.
3. Within 20 seconds of connecting the mains
power, press and hold the
STOP
button for 10
seconds.
The charger will respond with one flash from all
the lights.
4. For each press of the
STOP
button, the charger
moves down one step in the table
5
Содержание Access 30
Страница 2: ......
Страница 197: ...00086 mm 100 100 100 609 307 5 215 57 5 10 210 220 Fig 5 Casing A11 and A12 fan cooled 197 ...