Microplan LE050 Скачать руководство пользователя страница 5

5

CAUTIONS
BEFORE USE

The electronic levels are supplied in ABS 
anti-shock boxes. 
Inside each box you can find a complete 
set of components, needed for the  proper 
operation of the level (see the component 
list for each model).

Herewith are a few suggestions for the 
maintenance and proper use of your in-
strument:

Before measuring, clean thoroughly the 
surface to be checked and the base of the 
level with s

pecific detergents

 (Paste for 

granite, Art. TZ0510 – Liquid detergent, 
Art. DT0520). Never use wax, grease or 
water-based detergents for cleaning gra-
nite.

Never use the instrument close to 

magne-

tic fields

, as the measurements could be 

altered.

The surface plate to be checked should 
be 

levelled

 as closely as possible to avoid 

inaccuracies of the readings due to com-
pound errors.

Check the levelling of the plate or the sur-
face to be measured by using a spirit level 
following the instructions supplied with 
the Microplan plates (Test report).

Before starting the measurement, check 
the 

battery charge

, pushing the button 

‘Batt’ (VA110), or just checking that the 
display does not show ‘Low Bat’ (VD110 
and LE051).

 
Check the instrument periodically, to 

 

verify its calibration and  performance. A 

periodical check

 of the instrument can 

ensure better performance and lower 
maintenance costs over time.

 

Lato Etichetta

Label Side

L

0.22 

L

0.22 

L

0.22 

W

0.22 

W

0.5 

W

0.5 

W

W

Vista Inferiore

Bottom view

Содержание LE050

Страница 1: ...HANDBOOK for the model LE050 ELECTRONIC LEVELS...

Страница 2: ...2 Copyright 2013 Microplan Documento MT14 12 Versione 1 All rights reserved Microplan 2014...

Страница 3: ...rrors of straightness flat ness and parallelism Mounting and levelling of machinery Testing for inclination twist and flexion in civil engineering MICROPLAN GROUP offers a wide range of models to meet...

Страница 4: ...face This level can work in combination with another LE 301 level or with an LE 201 level in differential mode LE 050 This model allows a very easy use for any operator The galvanometer placed on the...

Страница 5: ...tic fields as the measurements could be altered The surface plate to be checked should be levelled as closely as possible to avoid inaccuracies of the readings due to com pound errors Check the level...

Страница 6: ...gh frequency mechanical vibrations Sensitivity is as high as 1 m m 0 2 second of arc The internal software manages the whole acquisition process the measures ave raging and the data display on a galva...

Страница 7: ...ccessories LE050 Art LE0432 LE050 Unit Battery charger included with unit LE0432 Art LE0435 Serial connection cable between level and PC optional Art LE0439 WPLAN Microplan Flatness Software opzional...

Страница 8: ...the half of the read value Example if you read 26 m in the position a adjust the poten tiometer to 13 m on position b 3 Repeat the same steps 1 2 by tur ning the level of 90 as shown hereun der The i...

Страница 9: ...of charge directly on the galvano meter during this phase the led located on the head of the instrument will light orange CHECKING THE CHARGE DURING THE USE It is possible at any time to check the cha...

Страница 10: ...le The cable connects the LE050 unit to the pc through the serial gate COM1 o COM2 and needs the use of WPLAN MICROPLAN Flatness sof tware Regarding the complete procedure for the memorized data captu...

Страница 11: ...3019 VARALLO Vercelli ITALY 39 0163 54619 569084 39 0163 564081 mpi microplan group com Skype microplanitalia www microplan group com TECHNICAL SUPPORT By doubt or information regarding the working of...

Страница 12: ...9 0163 564081 EMAIL mpi microplan group com SKYPE microplanitalia WEBSITE www microplan group com MICROPLAN FRANCE SAS 2 LA GRAULE F 23360 LA FORET DU TEMPLE FRANCE TEL 33 5 55806666 FAX 33 5 55806620...

Отзывы: