Microplan LE050 Скачать руководство пользователя страница 4

4

The models which are currently available 
are the result of research which has im-
proved the whole range, incorporating a 
new concept of the internal mechanism 
being submerged in an oil-bath box, and 
the microprocessor-based logic.

LE 101:

In this model the pendulum unit and the 
analog VA110 read-out unit are connected 
by means of a cable. The analog display 
allows the choice of 3 different measuring 
scales.  It is possible to connect two levels 
in the differential mode. Collection of data  
can be made through a serial port (optio-
nal) to be connected to the PC.

LE 201:

This intermediate model has a micropro-
cessor-based logic, and it shows the error 
by means of an integrated digital display, 
with the possibility to choose the unit of 
measurement in µm/m, seconds or µrad 
during calibration.  All of the procedures 
are achieved  by means of only three but-
tons, with the possibility to use the unit 
with the LE 301 model in differential 
mode.

LE 301:

This is the most complete model, also 
with  microprocessor-based logic,  and 
an integrated digital read-out unit, with 
the possibility to store the data and then 
transfer them to the PC with a connection 
cable. The Wplan Microplan software will 
elaborate the measurements taken with 
the electronic level, in order to present a 
plot of the measured surface.
This level can work in combination with 
another LE 301 level, or with an LE 201 
level, in differential mode.

LE 050:

This model allows a very easy use for any 
operator. 
The galvanometer placed on the front 
panel shows the error according to five 
different measuring scales.
It is made up of an alluminium structu-
re with black granite base, incorporating 
an analog display and a wooden handle. 
The internal mechanism is submerged 
in an oil-bath box. The level is powered 
by rechargeable batteries, with test but-
ton for battery status.

LE 051:

This traditional model has been concei-
ved for fast and easy use.
The galvanometer placed on the front pa-
nel shows the error according to five diffe-
rent measuring scales.
It is made up of a stabilised cast iron 
structure, incorporating an analog and 
digital display, a wooden handle and a 
spirit level. The internal mechanism is 
submerged in an oil-bath box. The level is 
powered by a rechargeable battery, and it 
has a button which indicates the status of 
battery charge.

LE 401:

The latest model of the Microplan level 
series works by means of radio transmis-
sion of the inclination values.
It has a sensor unit (LE401) and a sepa-
rate digital read-out unit (VD410). It has 
several functions, which can be achieved 
by means of a simple but complete in-
ternal menu. The internal mechanism is 
submerged in an oil-bath box, and it can 
read up to 10 different sensor units by 
means of a single VD410  read-out unit, 
in a range of action of 30 metres.

Содержание LE050

Страница 1: ...HANDBOOK for the model LE050 ELECTRONIC LEVELS...

Страница 2: ...2 Copyright 2013 Microplan Documento MT14 12 Versione 1 All rights reserved Microplan 2014...

Страница 3: ...rrors of straightness flat ness and parallelism Mounting and levelling of machinery Testing for inclination twist and flexion in civil engineering MICROPLAN GROUP offers a wide range of models to meet...

Страница 4: ...face This level can work in combination with another LE 301 level or with an LE 201 level in differential mode LE 050 This model allows a very easy use for any operator The galvanometer placed on the...

Страница 5: ...tic fields as the measurements could be altered The surface plate to be checked should be levelled as closely as possible to avoid inaccuracies of the readings due to com pound errors Check the level...

Страница 6: ...gh frequency mechanical vibrations Sensitivity is as high as 1 m m 0 2 second of arc The internal software manages the whole acquisition process the measures ave raging and the data display on a galva...

Страница 7: ...ccessories LE050 Art LE0432 LE050 Unit Battery charger included with unit LE0432 Art LE0435 Serial connection cable between level and PC optional Art LE0439 WPLAN Microplan Flatness Software opzional...

Страница 8: ...the half of the read value Example if you read 26 m in the position a adjust the poten tiometer to 13 m on position b 3 Repeat the same steps 1 2 by tur ning the level of 90 as shown hereun der The i...

Страница 9: ...of charge directly on the galvano meter during this phase the led located on the head of the instrument will light orange CHECKING THE CHARGE DURING THE USE It is possible at any time to check the cha...

Страница 10: ...le The cable connects the LE050 unit to the pc through the serial gate COM1 o COM2 and needs the use of WPLAN MICROPLAN Flatness sof tware Regarding the complete procedure for the memorized data captu...

Страница 11: ...3019 VARALLO Vercelli ITALY 39 0163 54619 569084 39 0163 564081 mpi microplan group com Skype microplanitalia www microplan group com TECHNICAL SUPPORT By doubt or information regarding the working of...

Страница 12: ...9 0163 564081 EMAIL mpi microplan group com SKYPE microplanitalia WEBSITE www microplan group com MICROPLAN FRANCE SAS 2 LA GRAULE F 23360 LA FORET DU TEMPLE FRANCE TEL 33 5 55806666 FAX 33 5 55806620...

Отзывы: