Micronor MR380-1-3 Скачать руководство пользователя страница 17

MR380-1-3 Instruction Manual 

Page 17 of 29 

 

Environmental Performance 

 

Temperature/Humidity 

-5°C to +55°C (23°F to +131°F), 0-95% RH, Non-Condensing  

Ingress Protection 

IP50  

Physical Attributes 

 

Mounting 

35mm DIN Rail 

Housing 

11.4 x 8.9 x 3.2 cm (4.5 x 3.5 x 1.25 inches) 

Weight 

230 g (8.1 oz) 

Specifications subject to change without notice 

 

 

 

MR387 Emergency Stop Switch 

 

Functionality 

 

ISO 13850 

ISO 13850 defines the characteristics and requirements for a traditional 
electromechanical E-STOP switch. The MR380 Sensor/Controller integrates the 
definition of purpose and functionality only. 

Functional States 

MR380-1-3 Universal Controller Output States 

Normal RESET (Up Position) 

Red LED is OFF 
Digital 5V and 24V Outputs=HI 
Relay NC contacts=Closed, Relay NO contacts=Open 

ACTIVATED (Down Position) 
Broken Fiber, Loss of Optical Signal, 
or Controller Failure 

Red LED is ON 
Digital 5V and 24V Outputs=LOW 
Relay NC contacts=Open, Relay NO contacts=Closed 

Functional Safety 

For MR387 E-Stop  MR380-1-3 Universal Controller

 

ISO 13849 

Category 2 

MTTF

d

 

4.14 E+06 hours (473.1 years) 

Performance Level 

PL=c 

Safety Integrity Level 

SIL=1 

Optical Interface 

 

Interface 

Duplex LC for pigtailed sensors, MR387-XX-YY where YY is pigtail length in meters 
ODVA IP-LC connector receptacle, MR387-XX-D00 sensors in housing 

Insertion Loss 

For calculating System Loss Budget: 
MR387-2X-XX, IL=2.5dB  max (2dB typical), 62.5/125 OM1 MM Fiber 
MR387-3X-XX, IL=5.0dB max (3dB typical), 9/125 OS1 SM Fiber 
MR387-5X-XX, IL=3.5dB max (3dB typical), 50/125 OM2/OM3 MM Fiber 
Consult Application Note AN118 for guidance on determining system loss budget 
and maximum distance 

Explosive Atmospheres 

Inherently Safe, Simple Mechanical Device 

EX Classification 

Inherently safe, simple mechanical device when used with MR380 Controller 
IECEx Test Report GB/CML/ExTR 16.0105.00/00 

ATEX 

 

EPL Mb/Gb/Gc/Db/Dc 

EAEU/GOST 

EPL Mb/Gb/Gc/Db/Dc 

IEC Ex 

EPL Mb/Gb/Gc/Db/Dc 

North America 

Exempt, non-electrical 

Environmental 

 

Temperature/Humidity 

-40°C to +65°C  (-40°F to +150°F), 0-95% RH, Non-Condensing  

Содержание MR380-1-3

Страница 1: ...43 4020 sales micronor ch www micronor ch Notice of Proprietary Rights The design concepts and engineering details embodied in this manual which are the property of MICRONOR LLC are to be maintained i...

Страница 2: ...claration of Conformity D1 12 1 2016 Corrected SIL typo is SIL1 PLc D2 3 2 2017 Added Single Mode Declaration of Conformity to Appendix D3 5 18 2017 Remove 850nm Multimode Option D4 9 27 2019 Single M...

Страница 3: ...Connections 11 3 4 2 MR380 1 3 and MR387 E Stop System Start Up Performance Check 12 4 Troubleshooting 13 Potential Issues Solutions 13 Damaged in Shipment 14 5 Warranty Information 15 6 Specification...

Страница 4: ...ly Hierarchy of E Stop Switch 10 Figure 6 E Stop Switch Orientation Interchangeable when Mounting into Optical Block 10 Figure 7 Front Panel Outputs of MR380 1 3 Controller Error Bookmark not defined...

Страница 5: ...location The entire fiber optic sensor system has a generous system loss budget enabling long distance systems complex routing and daisy chaining of multiple switches Depressing the switch interrupts...

Страница 6: ...e signaling detection that can be deployed in difficult hazardous environments and over very long distances The Microswitch employs a photo interrupt scheme operating over a duplex 62 5 125 m fiber op...

Страница 7: ...wo optical circuit configurations The Normally Open NO layout corresponds to an optical circuit that is open until the microswitch is depressed the Normally Closed NC layout corresponds to an optical...

Страница 8: ...1 3 Controller Module MR380 1 3 Controller Module Phoenix Terminal Block 1879599 inserted as part of unit Instruction Manual this document one soft copy supplied with each shipment MR387 series Sensor...

Страница 9: ...n LC Duplex optical cable is used to interconnect the sensor and controller The sensor incorporates a 3m optical pigtail or alternate length as specified by customer If a longer connection to the cont...

Страница 10: ...cal Reference Drawing in Section 9 2 Refer to Figure 6 below for switch orientation Secure panel mount switch with all appropriate designations and requirements Figure 6 E Stop Switch Orientation Inte...

Страница 11: ...a Phoenix Contact screw terminal For more information consult Controller specifications given in Section 6 1 If connectors are lost or damaged contact Micronor Sales for replacement details MR380 1 3...

Страница 12: ...do so at this time and verify that the EMERGENCY ON LED red is as shown below E Stop Switch Power LED Emergency ON LED 24V Digital Out 5V Digital Out Relay Contacts Not Depressed ON OFF Hi 20V Hi 4V...

Страница 13: ...or between 9 5dBm to 6 5dBm when using 9 125 m SM fiber Clean all fiber optic connector surfaces using appropriate cleaning materials 5V and 24V Digital Outputs No high voltage output Verify solid ele...

Страница 14: ...ite or call your nearest MICRONOR office in the U S A Please retain the shipping container in case reshipment is required for any reason If you receive a damaged instrument you should 1 Report the dam...

Страница 15: ...Repaired products are warranted for the balance of the original warranty period or at least 90 days Limitations of Warranty This warranty does not apply to defects resulting from unauthorized modific...

Страница 16: ...le Mode OS1 9 125 or SMF 28 System Loss Budget Minimum 23dB Typical 25dB Maximum Optical Link Length Distance is a function of user s system loss budget which is the total round trip loss of all optic...

Страница 17: ...Relay NO contacts Closed Functional Safety For MR387 E Stop Sensor MR380 1 3 Universal Controller ISO 13849 Category 2 MTTFd 4 14 E 06 hours 473 1 years Performance Level PL c Safety Integrity Level...

Страница 18: ...g IP65 Mechanical Housing Aluminum body anodized finish Durability 100 000 operations min Physical Housing Dimension Consult Mechanical Reference Drawing Mounting Consult Mechanical Reference Drawing...

Страница 19: ...the receiving fiber is only slightly smaller than the transmitting fiber there is a smaller loss that can be built into the system loss budget For example transmitting from OM1 fiber 62 5 m core to O...

Страница 20: ...tem The light source power is held constant under normal operating conditions allowing for a known system loss budget when designing a system Additionally the optics within the switch are designed to...

Страница 21: ...series permitted that the additional losses fall within the optical system loss budget Figure 11 illustrates a system using three MR387 switches in series For more information on System Loss Budget pl...

Страница 22: ...ll additional losses fall within the optical system loss budget This allows a single E stop to control multiple systems or switch off multiple sources of energy even if large distances separate the sy...

Страница 23: ...ual Page 23 of 29 9 Reference Documents See following pages for these reference drawings and documents MR380 1 Controller Reference Drawing MR387 E Stop Reference Drawing 2 pages MR380 Series Declarat...

Страница 24: ......

Страница 25: ......

Страница 26: ......

Страница 27: ...Page 1 of 19...

Страница 28: ...Page 2 of 19...

Страница 29: ...Page 3 of 19...

Отзывы: