6.
Specifications
For additional clarification of parameters related to Functional Safety, Laser Safety, Explosive
Atmospheres and CE Marking, consult Micronor document 93-0380-01, Declaration of Conformity.
MR380-1-3 Controller Module
Functional States
As Applies to MR387 E-Stop Sensor
Normal RESET (Up Position)
Red LED is OFF
Digital 5V and 24V Outputs=HI
Relay NC contacts=Closed, NO contacts=Open
ACTIVATED (Down Position)
Broken Fiber, Loss of Optical Signal,
or Controller Failure
Red LED is ON
Digital 5V and 24V Outputs=LOW
Relay NC contacts=Open, NO contacts=Closed
Digital Outputs
5V Logic
5 VDC/2k Ω Load Max
24V Logic
24 VDC/2k Ω Load Max
Relay Contacts
2x Form C (COM-NO-NC)
Switching Power Rating
60 W / 62.5 VA
Contact Material
AgNi, Gold Covered
DC Rating
75 V @ 0.75A; 24 V @ 2A
AC Rating
50 V @ 1A; 24 V @ 2A
Optical
Class I Eye Safe
Compatible Fibers
Multimode OM1 62.5/125 or OM2 50/125
Single Mode OS1 9/125 or SMF-28
System Loss Budget
Minimum 23dB, Typical 25dB
Maximum Optical Link Length
Distance is a function of user’s system loss budget which is the total round-trip loss
of all optical link components - sensor(s), connectors, splices and cable segments.
Consult Application Note AN118 for more information.
Contact Micronor for longer distance applications.
Interface
NOTE: Electrical connections shall not exceed 3 meters.
Electrical
10-pin Screw Terminal, 30-14 AWG (Phoenix Mating Plug 1803659)
Optical
LC-Duplex, 9/125 SM transmit fiber, 62.5/125 MM receive fiber
Power Supply
+24 VDC, <80 mA input
Functional Safety
For MR387 E-Stop MR380-1-3 Universal Controller
ISO 13849
Category 2
MTTFd
4.14 E+06 hours (473.1 years)
Performance Level (PL)
PL=c
Safety Integrity Level (SIL)
SIL=1
Explosive Atmospheres
Inherently Safe Optical Radiation
Ex Classification
Controller shall be installed in non-hazardous location only
Power supply to Controller shall be current limited to 200mA or less
IECEx Test Report (ExTR) GB/CML/ExTR 16.0105/00 (Multimode Controllers)
ATEX
EPL Mb/Gb/Gc/Db/Dc
IEC Ex
EPL Mb/Gb/Gc/Db/Dc
NEC
Exempt
Содержание MR380-1-3
Страница 24: ......
Страница 25: ......
Страница 26: ......
Страница 27: ...Page 1 of 19...
Страница 28: ...Page 2 of 19...
Страница 29: ...Page 3 of 19...