10
MICRONAIR AU8500 ULV TREE SPRAYER
The required total output from the sprayer is calculated by multiplying the coverage
of the sprayer (ha/min) by the volume application rate for the product being sprayed
(l/ha):
Flow from sprayer (l/min) =
Coverage (ha/min) x Application rate (l/ha)
If the pesticide is diluted before use, the volume application rate refers to the total
volume of the diluted mixture, not to the undiluted product.
Example:
Track spacing:
15 m
Vehicle speed:
10 Km/hr
Application rate:
2.0 l/ha
Coverage (ha/min)
=
Track spacing (m) x Tractor speed (Km/hr)
600
=
15
x
10 = 0.25
ha/min
600
Flow from sprayer (l/min) =
Coverage (ha/min) x Application rate (l/ha)
=
0.25 x 2.0
=
0.5 l/min (500 ml/min)
Speed
(Km/hr)
2
4
6
8
10
12
14
16
18
20
1
0.003 0.007 0.010 0.013 0.017 0.020 0.023 0.027 0.030 0.033
2
0.007 0.013 0.020 0.027 0.033 0.040 0.047 0.053 0.060 0.067
3
0.010 0.020 0.030 0.040 0.050 0.060 0.070 0.080 0.090 0.100
4
0.013 0.027 0.040 0.053 0.067 0.080 0.093 0.107 0.120 0.133
5
0.017 0.033 0.050 0.067 0.083 0.100 0.117 0.133 0.150 0.167
6
0.020 0.040 0.060 0.080 0.100 0.120 0.140 0.160 0.180 0.200
8
0.027 0.053 0.080 0.107 0.133 0.160 0.187 0.213 0.240 0.267
10
0.033 0.067 0.100 0.133 0.167 0.200 0.233 0.267 0.300 0.333
12
0.040 0.080 0.120 0.160 0.200 0.240 0.280 0.320 0.360 0.400
14
0.047 0.093 0.140 0.187 0.233 0.280 0.327 0.373 0.420 0.467
Track Spacing (m)
Table 1 – Coverage of Sprayer in Hectrares/minute