8
Example:
Required spray volume = 1 l/ha; Spray pass interval = 5m
Flow rate measured = 40 ml/min
Walking speed (m/s) =
=
Flow rate (ml/min)
6 x spray pass interval (m) x total spray volume (l/ha)
40
6 x 5 x 1
= 1.33
i.e. 1.33 m/s or 80 metres in one minute (1.33 x 60)
Mark out a distance of 80 metres and practice walking it in one minute.
WATER BASED PRODUCTS
Examples of mixing spray – for 1 hectare:
a) insecticide: 1litre
add water: +9 litres
Total volume: 10 litres
i.e. 1 part insecticide : 9 parts water
b) fungicide: 3 litres
add water: +17 litres
Total volume: 20 litres
i.e. 3 part insecticide : 17 parts water
The following table indicates the relationship between spray volume, flow rate and
walking speed for the ULVA+ as per the following formula:
Flow rate (ml/min) = 6 x spray pass interval (m) x total spray volume (l/ha) x walking speed (m/s)
Spray volume
(l/ha)
Spray pass
Interval (m)
Feed nozzle Flow rate*
(ml/min)
Walking speed
(m/s)
10 )
1.2
Red
90
1.0
10 ) Crop pests
2.5
Black
150
1.0
10 ) and diseases
3.0
Grey
175
1.0
15 )
2.0
Pink
195
1.1
20 )
1.5
Grey
175
1.0
* Note: Flow rates measured with water plus surfactant. Some products when mixed in water