TROUBLESHOOTING
A)
Atomiser disc spins but does not spray or sprays irregularly. Check:
−
the metering/ calibration nozzle. If the metering/calibration nozzle is blocked
remove and soak in soapy water. NB. Never blow through the nozzle with
your mouth.
−
the yellow feed nozzle. If the yellow feed nozzle is blocked remove and soak
in soapy water. NB. Never blow through the nozzle with your mouth.
−
the atomiser disc is clean and undamaged. Clean or replace if necessary.
−
the liquid ON/OFF valve for blockage. Clean if necessary.
B)
Atomiser disc fails to spin or spins unevenly. Check
−
that the batteries and balance weight are fitted correctly.
−
the condition of the batteries. Replace if necessary.
−
that electrical terminals and contact points are clean and that electrical wires
are not broken or corroded.
−
the motor for corrosion or obvious signs of wear. Replace if necessary.
−
the atomiser disc is fitted correctly.