Band saw blades are sharp enough to cause injury even when too blunt to cut wood!
It is recommended that protective gloves be worn when handling blades.
Unplug the band saw from the power source, slacken off the blade tension and open the upper and
lower housing doors with the aid of hex key provided.
Remove the blade retainer from the table.
Slide the blade off the upper and lower wheels, bringing it out of the machine via the slots in the rear
frame and the blade guard. Reverse these steps to fit the new blade. Ensure that the teeth are at the
front and pointing down.
Position the blade between the guide pins. Tension and adjust the tracking as done during the initial
set-up. Check and adjust, if necessary, the position of the two thrust bearings and the guide pins.
BLADE CHANGE
Table not shown in picture for
clearer view only; table does not
have to be removed for blade change
Содержание 86908
Страница 10: ...PARTS DIAGRAM...