background image

IB WatchBP Office Target BP3MD1-4 031010

Europe / Middle-East / Africa

Microlife AG

 

Espenstrasse 139

 

9443 Widnau, Switzerland

 

Tel +41 71 727 7000

 

Fax +41 71 727 7011

 

Email: [email protected]

 

www.watchbp.com 

Asia

Microlife Corporation 

 

9F, 431, RuiGang Road, NeiHu 

 

Taipei, 114, Taiwan, R.O.C.

 

Tel +886 2 8797 1288

 

Fax+886 2 8797 1283

 

Email: [email protected]

 

www.watchbp.com 

North / Central / South America

Microlife Medical Home Solutions, Inc. 

 

2801 Youngfield St., Suite 241

 

Golden, CO 80401, USA

 

Tel +1 303 274 2277

 

Fax +1 303 274 2244

 

Email: [email protected]

 

www.watchbp.com 

Read the instructions carefully before using this device.

Содержание WatchBP Office Targe

Страница 1: ...EN 1 Office blood pressure measurement device with built in Blood Pressure targets Instruction Manual ...

Страница 2: ...Blood Pressure Monitoring J Hypertens 2005 23 697 701 2 Pickering TG Hall JE Appel LJ et al Recommendations for Blood Pressure Measurement in Humans and Experimental Animals Part 1 Blood Pressure Measurement in Humans A Statement for Professionals From the Subcommittee of Professional and Public Education of the American Heart Association Council on High Blood Pressure Research Hypertension 2005 4...

Страница 3: ...Triple Mode Double Mode as option 10 Press 140 90 or 130 80 10 Traffic light indications Green light 11 Red light 11 Viewing and deleting of measurements Viewing the stored values 12 Pulse pressure PP 12 Deleting the stored values 13 Replacing slot in instruction card 13 Appendix Battery and power adaptor 14 15 Error messages 16 18 Safety care accuracy test and disposal 19 20 Technical specificati...

Страница 4: ... SYS mmHg DIA mmHg PUL min 1 3 3 SYS DIA PUL mmHg mmHg min Main Adaptor Cuff Socket Mode Switch Display Instruction M Button Memory Start Stop Button Product description Name of parts Battery Compartment ...

Страница 5: ...4 EN Target 1 140 90 Difference to Target setting Heart Beat Interval Time Battery Symbol Memory Triple Mode Target 2 130 80 Systolic Value Diastolic Value Pulse Pressure PP Pulse Rate 3 Display ...

Страница 6: ...omponents WatchBP Office Target Blood Pressure Device X 1 AC Adaptor X 1 Input 100 240V 50 60Hz 0 7A Output 6V 0 6A M size 22cm 32cm X 1 L size 32cm 42cm X 1 Instruction Manual X 1 Quick Start Guide X 1 3 SYS DIA PUL mmHg mmHg min ...

Страница 7: ...apter socket in the blood pressure monitor then Plug the adapter plug into the wall socket M Medium size 22 32 cm 8 7 12 6 inches L Large size 32 42 cm 12 6 16 5 inches Selecting the correct cuff Two different cuff sizes are provided with the WatchBP Office Target Medium and Large Use the cuff marker to select the cuff size that best matches the circumference of the patient s upper arm ...

Страница 8: ...he air tube and artery mark arrow point towards the lower arm 2 Lay the cuff on the arm Make sure that the lower edge of the cuff lies approximately 2 to 3cm to 1 inch above the elbow Connect the cuff to the device Connect the cuff to the device by inserting the cuff connector into the cuff connector socket 2 3cm 3 4to1inch ...

Страница 9: ...ring or constricting the arm to be measured 5 It may result in incorrect blood pressure readings if the cuff does not fit properly Use a different size cuff if the range index at the end of the cuff does not fall into the range specified by the range stripes 6 Apply the same steps to the other arm if a measurement of the other arm is required When the cuff is wrapped around the arm the edge of the...

Страница 10: ...by a single measurement 15 sec 1 2 Selecting the operation mode Standard or Triple mode Select an operation mode There are two measuring modes to be selected Standard mode standard single measurement or Triple mode automatic triple measurements To select Standard mode slide the switch on the right side of the device downwards to position 1 To select Triple mode slide this switch upwards to positio...

Страница 11: ...ne visit blood pressure measurement Press 140 90 or 130 80 button Press the button ON OFF 140 90 or ON OFF 130 80 to select the preferred target value The device will then start to inflate Do not remove the cuff between the measurements If one of the individual measurements is questionable an extra measurement will be taken automatically 3 SYS DIA PUL mmHg mmHg min Press either the ON OFF 140 90 o...

Страница 12: ...n green with two OK signs Additionally the lowest column in the screen shows the pulse pressure PP Red light If either the measured systolic or diastolic result is above the set target value 140 90 or 130 80 the screen will light in red with the difference to the desired value shown in display as number e g 24 22 Traffic Light Indication in the display ...

Страница 13: ... diastolic difference with the set target values 140 90 or 130 80 together with the pulse pressure PP Pulse Pressure The WatchBP Office Target device provides the pulse pressure PP of the patient pulse pressure systolic diastolic pressure Each measurement includes the calculation of a single PP value The average measurement will display the average PP value When viewing in Memory mode the PP value...

Страница 14: ...utton To permanently clear the memory press the M button while CL is flashing Single values cannot be cleared Replacing the inserted Instruction Card You can replace the inserted instruction card by pulling it out to the side and replacing the paper Extra cards are supplied with the instrument for this purpose 3 SYS DIA PUL mmHg mmHg min Press and hold 3 SYS DIA PUL mmHg mmHg min 3 SYS DIA PUL mmH...

Страница 15: ...t the battery symbol will flash as soon as the instrument is switched on flat battery displayed You cannot take any further measurements and must replace the batteries 1 Open the battery compartment at the back of the instrument by pushing inwards at the two arrows and pulling out the battery compartment cover 2 Replace the batteries ensure correct polarity as shown by the symbols in the compartme...

Страница 16: ...DC 6V 600mA supplied with the WatchBP Office Target to operate the device 1 Plug the adapter cable into the Power Plug of the WatchBP Office Target device 2 Plug the adaptor plug into the wall socket When the power adaptor is connected no battery power is consumed ...

Страница 17: ... please read through the information in this instruction manual carefully Error Description Potential cause and remedy Err 1 Signal too weak The pulse signals on the cuff are too weak Re position the cuff and repeat the measurement Err 2 Error signal During the measurement error signals were detected by the cuff caused for instance by movement or muscle tension Repeat the measurement keeping your ...

Страница 18: ...ements and then repeat the measurement Error Description Potential cause and remedy Err 3 No pressure in the cuff An adequate pressure cannot be generated in the cuff A leak may have occurred Replace the batteries if necessary Repeat the measurement Err 5 Abnormal result The measuring signals are inaccurate and no result can therefore be displayed Read through the checklist for performing reliable...

Страница 19: ... cuff pressure too high The pressure in the cuff is too high over 300 mmHg OR the pulse is too high over 200 beats per minute Relax for 5 minutes and repeat the measurement LO Pulse too low The pulse is too low less than 40 beats per minute Repeat the measurement ...

Страница 20: ...s and must be treated with caution The manufacturer cannot be held responsible for damage caused by incorrect application Observe the storage and operating conditions described in the Technical specifications section of this manual Ensure that children do not use the device unsupervised some parts are small enough to be swallowed Only activate the pump when the cuff tube is installed Do not use th...

Страница 21: ... or after mechanical impact e g being dropped Please contact Microlife to arrange for an accuracy test Cleaning the cuff DO NOT wash the cuff DO NOT iron the cuff cover Device care Clean the device with a soft dry cloth Disposal Batteries and electronic instruments must be disposed of in accordance with the locally applicable regulations ...

Страница 22: ...ts per minute pulse Cuff pressure display Range 0 299 mmHg Resolution 1 mmHg Static accuracy pressure within 3 mmHg or 2 of reading 200mmHg Pulse accuracy 5 of the readout value Voltage source 4 X 1 5V Batteries size AA Mains adapter DC 6V 1 A Reference to Standards Device standard Device corresponds to the requirements of the standard for noninvasive blood pressure monitor EN 1060 1 EN 1060 3 EN ...

Страница 23: ...ar guarantee from the date of purchase This guarantee is valid only on presentation of the guarantee card completed by the owner confirming date of purchase or purchase receipt Product WatchBP Office Target Product Number BP 3MD1 4 Date Name Address Date Telephone Email Guarantee card ...

Страница 24: ... Microlife Corporation 9F 431 RuiGang Road NeiHu Taipei 114 Taiwan R O C Tel 886 2 8797 1288 Fax 886 2 8797 1283 Email watchbp microlife com tw www watchbp com North Central South America Microlife Medical Home Solutions Inc 2801 Youngfield St Suite 241 Golden CO 80401 USA Tel 1 303 274 2277 Fax 1 303 274 2244 Email watchbp mimhs com www watchbp com Read the instructions carefully before using thi...

Страница 25: ......