background image

22

5.2. Displaying stored results

Press the 

MEMORY

button 

to display the stored readings. After all the segments

in the display have been shown, an average value of all the measurements in the
selected memory is displayed. This average is indicated by “

”.

When the 

MEMORY

button 

is pressed again, the individual readings (switching

between systolic, diastolic, pulse and date/time) of the last measurement stored are
displayed. If this measurement was taken in the 3MAM procedure,

bk

is

displayed. If an arrhythmia was detected during the measuring
process, the arrhythmia symbol

  

will be displayed, but not flashing.

Press the 

MEMORY

button 

x

again to move backwards through the stored readings.

If you do not press any buttons for approx. 1 minute, the device automatically switch-
es back to standby mode.

5.3. Deleting a measurement

Select the entry for the measurement you want to delete. Press and hold the 

START

button 

for approx. 10 seconds until the memory symbol 

aq

flashes. Confirm your

deletion request by pressing the 

MEMO

button 

x

. “

” appears briefly on the

display and 2 short beeps sound. The entry you selected has been deleted. The
display returns to standby mode.

5.4. Deleting memory

The data can be deleted from the memory selected by pressing and holding the

MEMORY

button 

x

for about 7 seconds. After 7 seconds, the display 

shows

” ( CLEAR ) which indicates that all data will be deleted.

Confirm your deletion request by pressing the 

MEMO

button 

x

again. Three short

beeps sound during the procedure.

6. Miscellaneous

6.1. Care and maintenance

• Remove the batteries before cleaning the unit.

• Never use strong detergents or hard brushes.

• Clean the unit with a soft cloth, moistened with mild soapy water. Do not let water

enter the unit. After cleaning, only use the unit when completely dry.

• Remove the batteries from the unit if you do not wish to use it for an extended

period of time, otherwise there is a risk of battery leakage.

• Do not expose the unit to direct sunlight, and protect it from dust and moisture.

• Only inflate the cuff when it is in position around the upper arm.

2G-IB-edit for NF1-2B_rev_2.3:MLU3AC1-JAN05-2  14-11-20   10:25  Page 22

Содержание BP3NF1-2B

Страница 1: ...INSTRUCTION MANUAL Blood Pressure Monitor Model BP3NF1 2B 2G IB edit for NF1 2B_rev_2 3 MLU3AC1 JAN05 2 14 11 20 10 25 Page 1 ...

Страница 2: ...ptor 3 3 Setting time and date 3 4 Setting the alarm 3 5 Setting up the user memory 3 6 Selecting the 3MAM measuring method 3 7 Switching beeps on off 4 Operation 4 1 Fitting the cuff 4 2 Correct position for taking readings 4 3 Taking blood pressure readings 4 4 Troubleshooting 4 5 Switching off the unit 4 6 IOS Android BT APPs instruction 5 Memory 5 1 Recording the results 5 2 Displaying stored ...

Страница 3: ...1 Explanation of symbols This instruction manual belongs to this device It contains important information about starting up and operation Read the instruction manual thoroughly Non observance of these instructions can result in serious injury or damage to the device WARNING These warning notes must be observed to prevent any injury to the user NOTE These notes give you useful additional informatio...

Страница 4: ...4 1 2 Know Your Unit 2G IB edit for NF1 2B_rev_2 3 MLU3AC1 JAN05 2 14 11 20 10 25 Page 4 ...

Страница 5: ...5 2G IB edit for NF1 2B_rev_2 3 MLU3AC1 JAN05 2 14 11 20 10 25 Page 5 ...

Страница 6: ...daptor akUser memory 1 2 alTime Date amDisplay of systolic pressure anDisplay of diastolic pressure aoDisplay of pulse rate apPulse symbol aqMemory symbol arUnit has detected an arrhythmia asBatteries low Please replace batteries btAlarm symbol bkSymbol for 3MAM mode blCountdown symbol bmBlood pressure bar display bnBluetooth icon 2G IB edit for NF1 2B_rev_2 3 MLU3AC1 JAN05 2 14 11 20 10 25 Page 6...

Страница 7: ...e cuff immediately Loosen the cuff and remove it from your arm Please contact either your dealer or Microlife directly Patients with a weak pulse wave should raise their arm and open and close their hand around 10 times before taking a reading This exercise optimizes the pulse wave and the measuring process The unit is only to be used for the specific purpose described in this instruction manual A...

Страница 8: ...essure and its measurement please contact your doctor To ensure the best results and long term satisfaction with your Microlife 3NF1 2B blood pressure monitor we recommend that you read the following operating and maintenance instructions carefully 2 1 Items suppliedand packaging Please check first of all that the device is complete and is not damaged in any way In case of doubt do not use it and ...

Страница 9: ...rried out according to strict international standards One strong argument in favour of taking blood pressure at home is the fact that the readings are taken in familiar surroundings under relaxed conditions The most important reading is the socalled baseline value the one taken before breakfast directly after getting up in the morning As far as it is possible you should always try to take your blo...

Страница 10: ...green borderline yellow or danger orange red range The classification is based on standards established by the National Institutes of Health JNC7 2003 The traffic light bar illuminates according to your measurement If your measurement has only the green bar your measurement is Normal according to NIH standards If your measurement shows the yellow bar your measurement is Pre Hypertension If your me...

Страница 11: ...al history When using the unit regularly and recording the values for your doctor you should visit the doctor from time to time to keep him updated When taking readings remember that the daily values are influenced by several factors Smoking consumption of alcohol drugs and physical exertion influence the measured values in various ways Measure your blood pressure before meals Before taking readin...

Страница 12: ...tch V The previous measuring results are saved WARNING BATTERY SAFETY INFORMATION Do not disassemble batteries Clean the battery and device contacts if necessary before putting in the batteries Remove discharged batteries from the device immediately Increased risk of leakage avoid contact with skin eyes and mucous membranes If battery acid comes in contact with any of this parts rinse the affected...

Страница 13: ...vice to standby mode If you do not press any buttons for 1 minute during the time setting the time setting mode switches off and appears in the clock display 1 You can set the date and time by pressing down the TIMER button W for several seconds until appears on the display 2 Press the TIMER button W again After you release the button appears on the display and appears below this 3 Press the TIMER...

Страница 14: ...3 3 Press the TIMER button W The display for entering the alarm time flashes Use the MEMO button x to enter the alarm time first the hours and then the minutes 4 Press the TIMER button W and the alarm symbol flashes Use the MEMO button x to switch between alarm on and alarm off To confirm your entries press the TIMER button W or the START button w Once the alarm has been set an acoustic signal sou...

Страница 15: ...ing method and for single measurement 3 Confirm your selection by pressing the START button w or press the TIMER button W to make the next setting Switch beep on off 3 7 Switching beeps on off Beeps sound when you take a measurement using the 3NF1 2B blood pressure meter You can switch off the beeps by making the following setting 1 To switch between beep on and beep off press and hold the TIMER b...

Страница 16: ...ars on the display 5 short beeps sound during the procedure 2 Next the sleeve u automatically inflates until the pressure required for a measure ment has been reached Alternatively you can create this pressure manually by pressing and holding the START button w after the device has automatically reached a pressure of at least 30 mmHg When you think that the device has reached the ideal starting pr...

Страница 17: ...Press the START button w The device carries out a self test Once this is complete appears on the display 5 short beeps sound during the procedure On the display you can see bk average and 1 for the first measurement 2 Next the sleeve u automatically inflates until the pressure required for a measurement has been reached Alternatively you can create this pressure manually by pressing and holding th...

Страница 18: ...ymbol ar will flash eight times while the reading is displayed You may also hear 8 short beeps these warn the user of an irregular heartbeat 11 If you do not press any buttons for approx 1 minute the device automatically switches to standby mode NOTE When the device is used the errors Err 1 2 3 5 6 can occur in the integrated circuit Err 6 can only occur in 3MAM mode In 3MAM mode errors Err 1 2 3 ...

Страница 19: ...nd repeat the measurement LO The pulse is too low less than 40 beats per minute Repeat the measurement 4 5 Switching off the unit If no buttons are pressed for approx 1 minute the device automatically switches to standby mode You can also switch to standby mode by pressing the START button w The blood pressure meter functions are now switched off The time and the selected user memory are continuou...

Страница 20: ...ces available for BT connection Select MTX BT to Pair Up Press 0000 to pair the devices 1 5 3NF1 2B Completes pairing with Smartphone 3NF1 2B Date Time Setting synchronized w Smartphone BT module remains On Broadcasting 1 6 User press Start button once or Wait for 60 Sec then 3NF1 2B turns Off Step 2 connect MTX with VitaDock App and do measurement MTX is switched of BT ON Off button is switched o...

Страница 21: ... BT icon Continuously Data Transfer Arrow Flashing 3 6 3NF1 2B Completes all BP Data Transfer 4 7 PC Link Software Functions This unit can be used in connection with your computer PC MAC running the PC Link blood pressure analyzer software Your computer will allow a capacity of monitoring 80 patients each with 1000 data note overuse will lower system efficiency The memory data can be transferred t...

Страница 22: ...es Confirm your deletion request by pressing the MEMO button x appears briefly on the display and 2 short beeps sound The entry you selected has been deleted The display returns to standby mode 5 4 Deleting memory The data can be deleted from the memory selected by pressing and holding the MEMORY button x for about 7 seconds After 7 seconds the display v shows CLEAR which indicates that all data w...

Страница 23: ...a recycling site or in a shop Consult your municipal authority or your dealer for information about disposal 6 3 Guidelines Standards Device standard Device corresponds to the requirements of the standard for non invasive blood pressure monitors AAMI ANSI IEC 80601 2 30 IEC 60601 1 IEC 60601 1 2 Bluetooth system to V3 0 FCC Part 15C Electromagnetic compatibility Device fulfills the stipulations of...

Страница 24: ...e measuring range 40 200 beats Min Maximum error tolerance for static pressure 3 mmHg Maximum error tolerance for pulse rate 5 of the reading Pressure generation Automatic using micro pump Deflation Automatic Operating conditions After approx 1 minute Operating conditions 10 C to 40 C 15 85 humidity Storage conditions 5 C to 50 C Dimensions approx 125 mm x 163 mm x 65 mm Cuff size Wide range easy ...

Страница 25: ...arisen due to improper treatment e g nonobservance of the user instructions b All damage which is due to repairs or tampering by the customer or unauthorised third parties c Damage which has arisen during transport from the manufacturer to the consumer or during transport to the service centre d Accessories which are subject to normal wear and tear cuff batteries etc 5 Liability for direct or indi...

Страница 26: ... equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This d...

Отзывы: