If you want to change the date and time 
again, press and hold the MAM & time but-
ton 

4

 down for approx. three seconds until 

the year starts to flash. Now you can enter 
the new values as described above.

Selecting the correct cuff

Microlife offers different cuff sizes. Select the cuff 
size to match the circumference of your upper arm 
(measured by close fitting in the centre of the upper 
arm).

 

If the cuff 

 coming with the monitor does not fit, 

please contact your local pharmacy which can order 
an alternative size for you.

Cuff size

for circumference of 

upper arm

S

17 - 22 cm

M

22 - 32 cm

M - L

22 - 42 cm

L - XL

32 - 52 cm

   

In addition to the soft cuffs in the above-

mentioned sizes, as an alternative, a 

preformed comfort cuff is available in M - L, 
one size fits all.

   

Use only aponorm

®

 cuffs manufactured by 

Microlife.

   

All aponorm

®

 cuffs are latex-free.

   

Connect the cuff to the monitor by inserting the 
cuff connector 

10

 into the cuff socket 

5

 as far 

as it will go.

Selecting multiple/MAM or individual 

measurement 

Please select before each measurement whether 
you want to perform a normal single measurement 
(NO MAM symbol 

14

 in the display) or a multiple/

MAM measurement (MAM symbol 

14

 visible in 

the display). In the MAM mode, three measure-
ments are automatically taken one after the other, 
the result from all measurements is automatically 
analysed and then displayed. As the blood pressu-
re varies constantly even within a very short time, 
a result determined in such a way is slightly more 
reliable than just one single measurement.

To select the MAM mode, press the MAM & time 
button  

4

 until the MAM symbol appears in the 

display. In order to return to the normal mode (indi-
vidual measurement), press the MAM button again 
until the MAM symbol is no longer displayed. 

  

During the measurement in the MAM mode, 
the number 1, 2 or 3 at the bottom right of the 
display shows which of the three measure-
ments is currently taken.

  

Between the individual measurements, there 
is an automatic pause of 15 seconds each, 
indicated by the spinning MAM waiting symbol 

19

. A countdown indicates the remaining time.

Содержание Aponorm Professional Control

Страница 1: ...of the most common causes of strokes user Arrhythmia detection storage slots Children Diabetics Kidney disease Also suitable for Pregnant women YEARS WARRANTY CLINICALLY VALIDATED Traffic light displa...

Страница 2: ...aponorm Professional Control D E...

Страница 3: ...ad the operating instructions before use Display 11 Systolic value 12 Diastolic value 13 Pulse indicator 14 MAM mode multiple measurement mode active 15 Stored value 16 Cuff check A Cuff position and...

Страница 4: ...rtension diabetes for pregnant women preg nant women suffering from preeclampsia patients suffering from atherosclerosis terminal kidney diseases obesity and for the elderly The monitor can detect irr...

Страница 5: ...developed and clinically tested in cooperation with internationally renowned medical specialists Atrial fibrillation is detected with a certainty of 97 to 100 1 2 If you have any questions or problem...

Страница 6: ...list for taking a reliable measurement 11 4 Taking the blood pressure 12 Manual inflation 13 How not to store a reading 13 How do I evaluate my blood pressure 13 Pulse arrhythmia detector PAD 13 5 Dat...

Страница 7: ...by a cardiologist based on his her interpre tation of an electrocardiogram Keep your arm still during the measurement in order to prevent incorrect results In patients with pacemakers or defibrillator...

Страница 8: ...d to know whether you suffer from atrial fibrillation For more information refer to the website of the monitor manufacturer Microlife at www microlife ch afib 2 Using the monitor for the first time In...

Страница 9: ...it will go Selecting multiple MAM or individual measurement Please select before each measurement whether you want to perform a normal single measurement NO MAM symbol 14 in the display or a multiple...

Страница 10: ...least 5 minutes Keep your feet flat on the floor and do not cross your legs Always take your blood pressure on the same arm normally the left one It is recommended that doctors perform double arm meas...

Страница 11: ...or 16 E In this case re position the cuff hold your arm still and repeat the measurement Read also chapter 8 on page 17 4 Once the correct pressure is reached the in flation stops and the pressure gra...

Страница 12: ...n the optimum green increased yellow or high red blood pressure range The classification corresponds to the fol lowing ranges defined by international guidelines ESH ESC JSH values in mmHg Range Systo...

Страница 13: ...ot included in the average Ensure that the maximum memory capacity of 99 values is not exceeded When the memory is full the oldest value is automatically over written with the 100th value Therefore th...

Страница 14: ...batteries Only use NiMH type reusable batteries When the flat battery symbol appears remove the batteries and recharge them They must not remain in the monitor as they may become destroyed exhaustive...

Страница 15: ...osed flyer 8 golden rules of taking the blood pressure For more detailed help in troubleshooting the monitor please refer to the download section of the www aponorm de product website Error Designa ti...

Страница 16: ...he measurement Error Designa tion Potential cause and remedy LO Pulse too low The pulse rate is too low less than 40 beats per minute Repeat the measurement Please consult your doctor if this or any o...

Страница 17: ...diagnosis It is not a substitute for a professional evaluation by a physician in parti cular not if the result does not correspond to the patient s physical condition Never rely on blood pressure meas...

Страница 18: ...cal provisions 10 Warranty terms We are confident in the quality of our aponorm blood pressure monitors Therefore we WEPA Apothekenbedarf GmbH Co KG grant end customers who are private consumers a vol...

Страница 19: ...ase or the warranty card filled in by the distributor directly to WEPA Apothekenbedarf GmbH Co KG or the distributor where the customer had purchased the product If the fault damage is covered by the...

Страница 20: ...play range 0 299 mmHg Measuring resolution 1 mmHg Static accuracy Pressure within 3 mmHg Pulse rate accuracy 5 of the readout value Voltage source 4 x 1 5 V alkaline batteries size AA Mains adapter DC...

Страница 21: ...Wepa_IB cover_BP_ ProfessionalControl_4G_1019 23...

Страница 22: ...ife ch Functional overview Important advice Inthedownloadsectionof www aponorm deyoufindtheseinstructionswith updatesindigitalformfordownload alsoinGerman Turkish FrenchandRussian Homepage Cuff check...

Отзывы: