Locker Mode Programming Instructions: 
 

Note: The lock must be unlocked to program in locker mode. User codes are one time use. 
 
 

CHANGE THE MASTER CODE (6 DIGITS) USING THE FACTORY MASTER CODE

 

P

 

● 

factory master code 

 

new master code 

☼ 

(6x) 

Example: 

P

 

● 

135243 

 

112233

  

☼ 

(6x) 

Result: factory master code 

135243

 was erased and new master code 

112233

 was accepted. 

 
 

LOCK USING A SINGLE USE USER CODE (4 DIGITS)

 

new user code 

 

turn knob to lock 

 

(3x)  

  

(every three seconds) 

Example: 1234 

 

turn knob to lock 

 

(3x)  

  

(every three seconds) 

Result: User code 

1234

 was created and the device was locked 

 
 

UNLOCK USING A SINGLE USE USER CODE 

 

new user code 

 

turn knob to unlock

 

Example: 1234 

 

turn knob to unlock 

Result: User code 

1234

 was used to unlock the lock. 

 
Note: The user code created in locker mode is a one time code, and is erased  when the 

Micro

IQ

  

is unlocked. 

 
 

 

P

 

 

master code 

 

Example: 

P

 

 

112233

 

 

Result: Master code 1

12233

 was used to unlock the 

Micro

IQ

 

Note: If the knob is left in the unlocked position for more than 20 seconds, the user code  
will be erased. However, if the 

Micro

IQ

 is left unlocked for less than 20 seconds, the user code 

will not be erased and the device can still be unlocked with that code. 
 

 

 

 
 

P

 

● 

old master code 

 

new master code 

☼ 

(6x) 

Example: 

P

 

● 

112233

 

 

123455

 

☼ 

(6x) 

Result: Old master code 

112233

 was erased and new master code 

123455

 was accepted. 

UNLOCK USING THE MASTER CODE

 

CHANGE THE MASTER CODE (6 DIGITS)

 