© Microhard Systems Inc.
21
3.0 Hardware Features
3.1.2 Connectors and Indicators
3.1.2.1 Front
On the front of the IPnXGii is the RS232 (COM2) port, CFG Button, RSSI, Tx, RX, CELL & CPU LED’s as
described below:
The
RS232
port is used for serial communication to serial
based end devices. (300bps to 921kbps)
CONFIG (Button) -
Holding this button depressed while
powering-up the IPnXGii will boot the unit into FLASH FILE
SYSTEM RECOVERY mode. The default IP address for
system recovery (only - not for normal access to the unit) is
static: 192.168.1.39.
If the unit has been powered-up for some time (>1 minute),
depressing the CFG Button for 8 seconds will result in FAC-
TORY DEFAULTS being restored, including the static factory
IP address. This IP address is useable in a Web Browser for
accessing the Web User Interface.
Tx(Red)/Rx(Green) LED’s -
The Tx/Rx LED’s indicate car-
rier (cellular) traffic. Also, during system bootup, the RF &
SGNL LED’s will flash.
Drawing 3-4:
IPnXGii Front View
Table 3-1: RS232 Pin Assignment
Signal Level
(dBm)
RSSI1
(Left)
RSSI2
(Mid)
RSSI3
(Right)
(-85, 0]
ON
ON
ON
(-90, -85]
ON
ON
FLASH
(-95, -90]
ON
ON
OFF
(-100, -95]
ON
FLASH
OFF
(-105, -100]
ON
OFF
OFF
(-109, -105]
FLASH
OFF
OFF
Other
SCANNING SCANNING SCANNING
Table 3-
2: RSSI LED’s
Name
Data Port
Input or
Output
DCD
1
O
RXD
2
O
TXD
3
I
DTR
4
I
SG
5
DSR
6
O
RTS
7
I
CTS
8
O
RING
9
O
CELL LED -
Indicates internal cellular module has
power.
Receive Signal Strength Indicator (RSSI) (3x
Green) -
As the received signal strength increases,
starting with the furthest left, the number of active
RSSI LEDs increases.
CPU LED -
The Status LED indicates that power has
been applied to the module. Flashing indicates boo-
tup or firmware upgrade status.
SIM Cards -
These slots are used to install SIM card
(s) provided by the cellular carrier to enable commu-
nication to their cellular network. Ensure that the SIM
card is installed properly by paying attention to the
diagram printed above the SIM card slot. The system
will detect which slot is used.
The factory default network
settings:
IP: 192.168.168.1
Subnet: 255.255.255.0
Gateway: 192.168.168.1