Factors to take into consideration when choosing a cable are:
•
price;
•
bend radius limitations (the lower performance cables generally can
bend more sharply)
•
performance requirements; and,
•
distance between the equipment and the antenna.
When installing the cable, always begin fastening at the top near the
antenna connector/surge arrestor. The cable must be supported at the top
with a hose clamp or wrap lock, and at 5 ft intervals down the length of the
tower. Over-tightening the fasteners will dent the cable and reduce
performance. If properly grounded surge arrestors are not installed at both
the top and the bottom of the cable, then the cable should be grounded to
the tower at these locations using a cable grounding kit. If the tower is non-
conductive, then a separate conductor, physically separate from the cable,
should be run down the tower.