© Microhard Systems Inc.
CONFIDENTIAL
84
IP9xx Series
6.0 Configuration
Destination Unit
1-65535
Values
As the name implies, this register specifies the ultimate destination
for an IP Series‘s data. Different network topologies dictate the
configuration of the Destination Unit (address):
For a Remote in a Point-to-Multipoint network, this menu option will
not appear: by definition, the destination is the Master (UA = 1).
For the Master in PMP, its Destination Unit (Address) is 65535
—the
broadcast address as it sends its data to all points.
In a Point-to-Point configuration, the destination is to be specified
(for a Remote: the Master); in the Master‘s Radio Configuration,
specify the Unit Address of the Remote Unit to which it is to send its
data.
In Peer-to-
Peer, the Remotes are configured with the target peer‘s
UA as the Destination Address, the Master with 65535; in Everyone
-to-Everyone, the Destination Address for ALL units is 65535 - the
broadcast address - as every unit sends its data to every other unit
(through the Master). E2E is a very bandwidth intensive network
topology.
Tx Control
On
Off
Values
This configuration option does not apply to a Master IP Series.
On (the default) permits the IP Series to transmit, i.e. RF emissions
are enabled.
Off configures the IP Series for RECEIVE ONLY. If ‗Off‘ is
selected, ‗On‘ may only be selected LOCALLY or via a special UDP
packet sent from the DiscoverIP Utility.
Содержание IP-921
Страница 165: ... Microhard Systems Inc CONFIDENTIAL 165 IP9xx Series Appendix B Upgrade Process DOS Prompt ...
Страница 166: ... Microhard Systems Inc CONFIDENTIAL 166 IP9xx Series Appendix B Upgrade Procedure DOS Prompt ...
Страница 169: ... Microhard Systems Inc CONFIDENTIAL 169 IP9xx Series Appendix E Mounting Dimensions ...
Страница 173: ...150 Country Hills Landing NW Calgary Alberta Canada T3K 5P3 Phone 403 248 0028 Fax 403 248 2762 www microhardcorp com ...