© Microhard Systems Inc.
CONFIDENTIAL
15
IP9xx Series
2.0 Quick Start
2.2 Text UI Method
(See Section 6.2 for more information re the Text User Interface.)
2.21 Required Materials
2 IP Series (with factory default configuration), each
with Power Adapter and Rubber Ducky Antenna
1
PC with NIC (ethernet) card and COM (serial) port
with HyperTerminal (or equivalent) application
1
Available connection to LAN*
1
Crossover patchcable (ethernet)*
1
MHS Diagnostic Cable (P/N MHS044000, black)
*dependent on desired test set-up
2.22 Set-Up Procedure
Connect a Rubber Ducky antenna to each IP Series.
Connect the Power Adapters to available 120VAC out-
lets, and to the IP Series.
Connect the MHS Diagnostic Cable to COM2 (front) of
one IP Series and the other end to an available COM
port on the PC.
Run HyperTerminal (or equivalent terminal program) on
the PC and configure it for the COM port chosen above,
115200bps, 8 data bits, no parity, 1 stop bit, and no flow
control.
Activate the HyperTerminal connection.
A login prompt will appear. Enter
admin
.
At the password prompt, enter
admin
.
continued...
Use the MHS-supplied power
adapter or an equivalent power
source.
Содержание IP-921
Страница 165: ... Microhard Systems Inc CONFIDENTIAL 165 IP9xx Series Appendix B Upgrade Process DOS Prompt ...
Страница 166: ... Microhard Systems Inc CONFIDENTIAL 166 IP9xx Series Appendix B Upgrade Procedure DOS Prompt ...
Страница 169: ... Microhard Systems Inc CONFIDENTIAL 169 IP9xx Series Appendix E Mounting Dimensions ...
Страница 173: ...150 Country Hills Landing NW Calgary Alberta Canada T3K 5P3 Phone 403 248 0028 Fax 403 248 2762 www microhardcorp com ...