8
000-255
Cool white 0% ~ 100%
LED ARRAY:
CLEANING AND MAINTENANCE
Caution: DANGER TO LIFE!
Disconnect from mains before starting maintenance operation!
The operator has to make sure that safety-relating and machine-technical installations are inspected by an expert after
every four years in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are inspected by a skilled
person once a year.
The following points have to be considered during the inspection:
1) All screws used for installing the devices or parts of the device must be tightly connected.
2) There must not be any deformations on housings, fixations and installation spots (ceiling, suspension, trussing).
3) The electric power cables must not show any damages, material fatigue (e.g. porous cables) or sediments.
Further instructions depending on the installation spot and usage have to be adhered by a skilled installer and any
safety problems have to be removed.
Replacing the fuse
If the fine-wire fuse of the device fuses, only replace the fuse by a fuse of same type and rating.
Before replacing the fuse, unplug mains lead.
Procedure:
Step 1: Unscrew the fuseholder on the rearpanel with a fitting screwdriver from the housing (anticlockwise).
Step 2: Remove the old fuse from the fuseholder.
Step 3: Install the new fuse in the fuseholder.
Step 4: Replace the fuseholder in the housing and fix it.
TECHNICAL SPECIFICATIONS:
Power supply: 100~240 V AC, 50/60 Hz ~
Power consumption: 120 W
DMX control channels: 3,5,9, 12 or 17 chs
DMX512 connection: 3-pin XLR
Sound-control: via built-in microphone
LED type: 30 W COB Tri-color RGB
Number of LEDs: 4
Beam angle: 30°
Dimensions (LxWxH): 425 x 187 x 163 mm
Weight: 4 kg
Maximum ambient temperature Ta: 40°
Maximum housing temperature TC (steady state): 80° C
Min. distance from flammable surfaces: 0.5 m
Min. distance to lighted object: 0.1 m
Fuse: T 2 A, 250 V
1
2
3
4